🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand DX3 AC MCB · 1P+N · 10 A · C curve · 408612408612↓ 33% off MRP1 / 3
BrandLegrand
CategorySwitchgear
SpecificationMiniature circuit breaker · 1P+N · 10 A · C curve
Brand SKU408612
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Legrand· In stock
Visit the Legrand store

Legrand DX3 AC MCB · 1P+N · 10 A · C curve · 408612

₹929/pcincl. GST-33%
₹787 + 18% GST · MRP ₹1,389
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹929 /pc incl. GST
Free delivery over ₹4,000

Legrand DX3 AC MCB · 1P+N · 10 A · C curve · 408612: Elume price today ₹929 per pc incl. GST, 33% below the ₹1,389 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹751, ₹178 less than here. The lowest tracked seller lists it at ₹751, ₹178 below it (tell us and we match it).

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
24 Aug to 22 Nov
₹1,858₹1,566₹1,274₹983₹691₹1,389₹929₹751
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹929
Avg market price
₹751
MRP
₹1,389
Lowest in view · 7 Oct
₹743
Highest in view · 23 Oct
₹929
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
SP
10 A
C
-
₹787 +GST /pc
₹929 incl. GST
Viewing above ↑
MCB
SP
10 A
C
6 kA
₹104 +GST /pc
₹123 incl. GST
MCB
SP
10 A
C
7.5 kA
₹116 +GST /pc
₹137 incl. GST
MCB
SP
10 A
C
10 kA
₹153 +GST /pc
₹181 incl. GST
MCB
SP
10 A
C
10 kA
₹170 +GST /pc
₹201 incl. GST
MCB
SP
10 A
C
10 kA
₹206 +GST /pc
₹243 incl. GST
MCB
SP
10 A
C
10 kA
₹206 +GST /pc
₹243 incl. GST
MCB
SP
10 A
-
-
₹217 +GST /pc
₹256 incl. GST
MCB
SP
10 A
-
-
₹239 +GST /pc
₹282 incl. GST
MCB
SP
10 A
C
15 kA
₹246 +GST /pc
₹290 incl. GST
MCB
SP
10 A
-
7.5 kA
₹253 +GST /pc
₹299 incl. GST
MCB
SP
10 A
-
7.5 kA
₹259 +GST /pc
₹306 incl. GST
MCB
SP
10 A
C
-
₹280 +GST /pc
₹330 incl. GST
MCB
SP
10 A
-
10 kA
₹314 +GST /pc
₹370 incl. GST
MCB
SP
10 A
C
-
₹321 +GST /pc
₹379 incl. GST
MCB
SP
10 A
C
15 kA
₹360 +GST /pc
₹425 incl. GST
MCB
SP
10 A
-
15 kA
₹432 +GST /pc
₹510 incl. GST
MCB
SP
10 A
C
15 kA
₹468 +GST /pc
₹552 incl. GST
MCB
SP
10 A
-
15 kA
₹486 +GST /pc
₹574 incl. GST
MCB
SP
10 A
-
15 kA
₹523 +GST /pc
₹617 incl. GST
MCB
SP
10 A
C
10 kA
₹655 +GST /pc
₹773 incl. GST
MCB
SP
10 A
C
10 kA
₹901 +GST /pc
₹1,063 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹910/pc on this product, applied automatically

Legrand DX3-SPN C10A AC MCB

As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DX3 AC MCB · 1P+N · 10 A · C curve · 408612 · 408612
Device typeMiniature circuit breaker (MCB)
SeriesDX3
Poles1P+N (SPN)
Rated current10 A
Trip curveC curve
Warranty5 years if mounted inside Legrand DB
Country of originIndia
Current rating10 A
Reference standardIS/IEC 60898-1
BrandLegrand
Brand SKU408612
ELINE6CFMJKGK7
Sold asPer pc
ColorRAL7035
Product Code408612
Product features➥10 kA ISI marked as per IS/IEC 60898-1 2002➥Integrated label holder➥Sliding bottom clamp➥Improved air channels➥Color coded On/Off indication on dolly➥Biconnect lower terminals➥IP 20 protected terminals➥Sliding shutters➥DC - 80 V per pole - 1 kA Can be supplied either by copper cable, prong busbar (top side or bottom side) or fork busbar (bottom side). Protected against solid bodies larger than 12,5mm ("fingerproof"): IP20 according to IEC/EN 60529 standard.Maximum level of limitation of the let through energy (energy limitation class 3 according to IEC 60898-1 standard). Can be equipped with Legrand DX3 auxiliaries and accessories.Can be connected to aluminium cable with Legrand DX3 terminal accessory n° 4 063 10. This device complies with substance-restriction requirements and has been designed in an environmentally conscious process.
Product Width (mm)35.4
Mechanism / AccessoriesMechanism
Ratings as published by Legrand (shop.legrand.co.in). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet