🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Out of stock · 3 alternativesHavells · SP C MCB · 6 A · DHMXCSPZ006₹123₹209
Orient Eurotech MCB Single Pole With Neutral · Curve C · 06 A101SNC0060↓ 21% off MRP
BrandOrient
CategorySwitchgear
Specification06 A · 1P
Brand SKU101SNC0060
AvailabilityOut of stock
DeliveryPan-India · 7 working days
Orient· Out of stock
Visit the Orient store

Orient Eurotech MCB Single Pole With Neutral · Curve C · 06 A

Rating: 06A
struck through = out of stock
₹1,012/pcincl. GST-21%
₹858 + 18% GST · MRP ₹1,289
Out of stock
This one cannot be ordered right now. These match its specification and are in stock:
Same specificationMCB · SP · 6 A
HavellsIn stock
SP C MCB · 6 A · DHMXCSPZ006
₹123incl. GST/pc-41%
MRP ₹209
HoneywellIn stock
Impact MCB · 1P (SP) · 6 A · B curve · 10 kA · IH31P0B006
₹240incl. GST/pc-20%
MRP ₹300
ABBIn stock
MCB, SB200M - 6A 1P (SP) B Curve 10kA · 1SYS271012R0065
₹243incl. GST/pc-53%
MRP ₹515
Compare all 24 in-stock alternatives ↓
Need this exact model? Email info@elumenuvo.com and we will source it for you.
💳 30 Day credit facility available launching soon - join waitlist.

Orient Eurotech MCB Single Pole With Neutral · Curve C · 06 A: Elume price today ₹1,012 per pc incl. GST, 21% below the ₹1,289 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
24 Aug to 22 Nov
₹1,448₹1,321₹1,194₹1,068₹941₹1,289₹1,012
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹1,012
MRP
₹1,289
Lowest in view · 22 Sep
₹1,012
Highest in view · 3 Oct
₹1,063
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
SP
6 A
-
-
₹858 +GST /pc
₹1,012 incl. GST
Viewing above ↑
MCB
SP
6 A
C
6 kA
₹104 +GST /pc
₹123 incl. GST
MCB
SP
6 A
B
6 kA
₹104 +GST /pc
₹123 incl. GST
MCB
SP
6 A
C
7.5 kA
₹116 +GST /pc
₹137 incl. GST
MCB
SP
6 A
B
-
₹141 +GST /pc
₹166 incl. GST
MCB
SP
6 A
C
10 kA
₹153 +GST /pc
₹181 incl. GST
MCB
SP
6 A
C
10 kA
₹170 +GST /pc
₹201 incl. GST
MCB
SP
6 A
B
10 kA
₹203 +GST /pc
₹240 incl. GST
MCB
SP
6 A
B
10 kA
₹206 +GST /pc
₹243 incl. GST
MCB
SP
6 A
C
10 kA
₹206 +GST /pc
₹243 incl. GST
MCB
SP
6 A
-
-
₹217 +GST /pc
₹256 incl. GST
MCB
SP
6 A
-
-
₹239 +GST /pc
₹282 incl. GST
MCB
SP
6 A
B
10 kA
₹246 +GST /pc
₹290 incl. GST
MCB
SP
6 A
C
15 kA
₹246 +GST /pc
₹290 incl. GST
MCB
SP
6 A
-
7.5 kA
₹253 +GST /pc
₹299 incl. GST
MCB
SP
6 A
-
7.5 kA
₹259 +GST /pc
₹306 incl. GST
MCB
SP
6 A
C
-
₹280 +GST /pc
₹330 incl. GST
MCB
SP
6 A
D
10 kA
₹286 +GST /pc
₹337 incl. GST
MCB
SP
6 A
-
10 kA
₹314 +GST /pc
₹370 incl. GST
MCB
SP
6 A
C
-
₹321 +GST /pc
₹379 incl. GST
MCB
SP
6 A
D
10 kA
₹355 +GST /pc
₹419 incl. GST
MCB
SP
6 A
C
15 kA
₹360 +GST /pc
₹425 incl. GST
MCB
SP
6 A
D
-
₹385 +GST /pc
₹454 incl. GST
MCB
SP
6 A
B
15 kA
₹397 +GST /pc
₹468 incl. GST
MCB
SP
6 A
-
15 kA
₹436 +GST /pc
₹514 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹961/pc on this product, applied automatically

Bi-Directional Connection Terminal- Ensures easy and reliable connection from both line and load sides. Advanced Air Circulation Channels- Designed for efficient heat dissipation and enhanced performance. Easy Dismantling Mechanism- Provides convenient installation and maintenance. Positive Flag Indication- Clear visual indication for ON/OFF or trip status. Pad Locking Provision- Enables secure locking for added operational safety. Protective Terminal Covers- Enhances user safety by preventing accidental contact. SDB Technology- Integrated advanced technology for improved operational reliability. Overheat Sensing Technology- Detects abnormal temperature rise for enhanced protection. No Manual Thermal Bi-Metal Adjustment Required- Factory-calibrated design ensures consistent performance and reliability. Reduced Welding Joints- Improves product durability and electrical efficiency. Enhanced Arc Quenching System- Provides faster and safer arc suppression during operation. Line-Load Reversibility- Allows flexible installation from either side. Easy DIN Rail Clipping- Ensures quick and hassle-free mounting. Low Power Consumption- Optimized design for improved energy efficiency. 35 mm² Cable Terminal Capacity- Supports larger cable sizes for better connectivity. RoHS Compliant- Manufactured in accordance with environmental safety standards. IP20 Protection- Provides protection against accidental finger contact with live parts

As published by Orient. Verify critical parameters against the datasheet before specifying.
Orient Orient Eurotech MCB Single Pole With Neutral · Curve C · 06 A · 101SNC0060
Poles1P+N (SPN)
Rated current6 A
Trip curveC curve
Device typeMiniature circuit breaker (MCB)
Current rating06 A
Reference standardIS/IEC 60898-1
BrandOrient
Brand SKU101SNC0060
ELINEJPGH9MFHF
Sold asPer pc
Ratings as published by Orient (orientelectric.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What current is this MCB rated for and what wire should I use with it?

This MCB is rated 06A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet