🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Havells MCB SP B Curve · 6 A · DHMGBSPF006DHMGBSPF006↓ 40% off MRP1 / 4
BrandHavells
CategorySwitchgear
Specification1P (SP) · 6 A · B curve
Brand SKUDHMGBSPF006
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Havells· In stock★4.0(1)
Visit the Havells store

Havells MCB SP B Curve · 6 A · DHMGBSPF006

Size: 6 A
₹166/pcincl. GST-40%
₹141 + 18% GST · MRP ₹278
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹166 /pc incl. GST
Free delivery over ₹4,000

Havells MCB SP B Curve · 6 A · DHMGBSPF006: Elume price today ₹166 per pc incl. GST, 40% below the ₹278 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹168, the same as here. The lowest tracked seller lists it at ₹168, ₹2 above the Elume price.

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
24 Aug to 22 Nov
₹312₹273₹233₹194₹154₹278₹168₹166
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Matches the market price.
Elume today
₹166
Avg market price
₹168
MRP
₹278
Lowest in view · 22 Sep
₹166
Highest in view · 3 Oct
₹174
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
SP
6 A
B
-
₹141 +GST /pc
₹166 incl. GST
Viewing above ↑
MCB
SP
6 A
B
6 kA
₹104 +GST /pc
₹123 incl. GST
MCB
SP
6 A
B
10 kA
₹203 +GST /pc
₹240 incl. GST
MCB
SP
6 A
B
10 kA
₹206 +GST /pc
₹243 incl. GST
MCB
SP
6 A
-
-
₹217 +GST /pc
₹256 incl. GST
MCB
SP
6 A
-
-
₹239 +GST /pc
₹282 incl. GST
MCB
SP
6 A
B
10 kA
₹246 +GST /pc
₹290 incl. GST
MCB
SP
6 A
-
7.5 kA
₹253 +GST /pc
₹299 incl. GST
MCB
SP
6 A
-
7.5 kA
₹259 +GST /pc
₹306 incl. GST
MCB
SP
6 A
-
10 kA
₹314 +GST /pc
₹370 incl. GST
MCB
SP
6 A
B
-
₹353 +GST /pc
₹417 incl. GST
MCB
SP
6 A
B
15 kA
₹397 +GST /pc
₹468 incl. GST
MCB
SP
6 A
-
15 kA
₹436 +GST /pc
₹514 incl. GST
MCB
SP
6 A
-
15 kA
₹486 +GST /pc
₹574 incl. GST
MCB
SP
6 A
-
15 kA
₹523 +GST /pc
₹617 incl. GST
MCB
SP
6 A
B
10 kA
₹655 +GST /pc
₹773 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹163/pc on this product, applied automatically

Havells MCB SP B Curve is a switchgear product from Havells. Key ratings: rated current 6 A, poles 1P (SP), trip curve B curve.

  • Application : Suitable for protection against overload & short circuit for Lighting & other Domestic Loads
  • Rating : 06 A to 40 A
  • Specification : IS/IEC 60898-1
As published by Havells. Verify critical parameters against the datasheet before specifying.
Havells Havells MCB SP B Curve · 6 A · DHMGBSPF006 · DHMGBSPF006
Poles1P (SP)
Rated current6 A
Trip curveB curve
Country of originIndia
Device typeMiniature circuit breaker (MCB)
Current rating6 A
Reference standardIS/IEC 60898-1
BrandHavells
Brand SKUDHMGBSPF006
ELINEKPCG9M26F
Sold asPer pc
TypeB Curve
Rating6 A
Execution poleSingle Pole (SP)
Ratings as published by Havells (havells.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

★4.0(1)
★4.0✓ VerifiedTanya Kalra · 20 Oct

Good service and timely delivery