🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 30 mA · Type AC · BG204003BG204003↓ 34% off MRP
BrandLauritz Knudsen
CategorySwitchgear
SpecificationRCCB · 2P (DP) · 40 A · 30 mA · Type AC · 240 V AC · 2 M
Brand SKUBG204003
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Lauritz Knudsen· In stock
LVisit the Lauritz Knudsen store

Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 30 mA · Type AC · BG204003

Sensitivity: 30mA
Current Rating: 40A
$47.56/pc-34%
MRP $72.02
Wholesale · 15+ units
$45.18 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$47.56 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
$47.56 /pc
Viewing above ↑
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
$30.43 /pc
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
$30.78 /pc
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
$31.68 /pc
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
$33.98 /pc
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
$43.19 /pc
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
$56.62 /pc
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
$108.86 /pc
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
$137.42 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $45.18/pc on this product, applied automatically

Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 30 mA · Type AC is an RCCB from Lauritz Knudsen. It trips on earth-leakage current to protect people and wiring against electric shock and fire; it is fitted upstream of the MCBs it covers. Key ratings: Poles 2P (DP), Rated current 40 A, Sensitivity 30 mA, Type AC, Rated voltage 240 V AC, Width 2 M. It is built to IS 12640 (Part 1), IEC 61008-1.

  • Truly current operated: works even at reduced supply voltage
  • Core-balance current transformer (CBCT) sensing
  • Advanced neutral mechanism
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 30 mA · Type AC · BG204003 · BG204003
Device typeResidual current circuit breaker (RCCB)
SeriesEXORA
Poles2P (DP)
Rated current40 A
Sensitivity (IΔn)30 mA
RCCB typeType AC
Rated voltage240 V AC
Width2 modules
Reference standardIS 12640 (Part 1), IEC 61008-1
Current rating40 A
Sensitivity30 mA
BrandLauritz Knudsen
Brand SKUBG204003
ELINERJHHGGC7H
Sold asPer pc
Ratings as published by Lauritz Knudsen (Elume catalogue; Lauritz Knudsen smartshop; Lauritz Knudsen price list Aug 2026; Product name). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
THIS UNIT
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 30 mA · Type AC · BG204003 genuine and warranty-backed?

Yes. Every Lauritz Knudsen product on Elume is 100% genuine, sourced through authorised channels, and carries the manufacturer's standard warranty.

Do you deliver outside India?

Yes, to every country except Pakistan, North Korea, Iran, Syria, Cuba, Russia, Belarus and Afghanistan, and the Crimea, Sevastopol, Donetsk, Luhansk, Zaporizhzhia and Kherson regions. The delivery fee depends on weight and destination and is shown at checkout; international orders are paid by card in US dollars. The full rules are on our shipping page.

Is there a wholesale or bulk rate?

Yes. Orders of 15 or more pcs get a wholesale price below the listed Elume price, applied automatically and shown on every product page.

No reviews yet