🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB FW202 RCCB · 2P (DP) · 40 A · 30 mA · Type AC · 10 kA · 1SYF602015R14001SYF602015R1400↓ 7% off MRP
BrandABB
CategorySwitchgear
SpecificationRCCB · 2P (DP) · 40 A · 10 kA · 30 mA
Brand SKU1SYF602015R1400
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB FW202 RCCB · 2P (DP) · 40 A · 30 mA · Type AC · 10 kA · 1SYF602015R1400

₹2,121/pcincl. GST-7%
₹1,797 + 18% GST · MRP ₹2,284
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹2,121 /pc incl. GST
Free delivery over ₹4,000

ABB FW202 RCCB · 2P (DP) · 40 A · 30 mA · Type AC · 10 kA · 1SYF602015R1400: Elume price today ₹2,121 per pc incl. GST, 7% below the ₹2,284 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹1,697, ₹424 less than here.

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹2,444₹2,220₹1,995₹1,771₹1,547₹2,284₹2,121₹1,697
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹2,121
Avg market price
₹1,697
MRP
₹2,284
Lowest in view · 10 Aug
₹1,663
Highest in view · 3 Oct
₹2,227
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹1,797 +GST /pc
₹2,121 incl. GST
Viewing above ↑
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹2,007 +GST /pc
₹2,368 incl. GST
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹2,551 +GST /pc
₹3,010 incl. GST
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹2,619 +GST /pc
₹3,091 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹2,809 +GST /pc
₹3,315 incl. GST
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹3,344 +GST /pc
₹3,946 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹3,858 +GST /pc
₹4,552 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹4,444 +GST /pc
₹5,244 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹4,919 +GST /pc
₹5,804 incl. GST
RCCB
2P / 1P+N (single phase)
40 A
n/a
30 mA
₹7,696 +GST /pc
₹9,081 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹2,015/pc on this product, applied automatically

The RCCBs FW200 series assures protection to people and installations against fault current to earth. This product is manufactured according to IEC, IS Standards for the markets where it is required.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB FW202 RCCB · 2P (DP) · 40 A · 30 mA · Type AC · 10 kA · 1SYF602015R1400 · 1SYF602015R1400
Device typeResidual current circuit breaker (RCCB)
Poles2P (DP)
Rated current40 A
Breaking capacity10 kA
Sensitivity (IΔn)30 mA
RCCB typeType AC
Width2 modules (35 mm)
Net weight0.159 kg
Current rating40 A
Sensitivity30 mA
Reference standardIS 12640-1 / IEC 61008
BrandABB
Brand SKU1SYF602015R1400
ELINECR3GJPP4P
Sold asPer pc
Ratings as published by ABB (Product name; shop.in.abb.com listing for 1SYF602015R1400, 14 Sep 2026; abb.com product data). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
THIS UNIT
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.

No reviews yet