Schneider Schneider PowerLogic PM3255 Power Meter · 1P/3P · 5 A · Class 0.5S active energy · METSEPM3255 · METSEPM3255
Rated current5 A
Ingress protectionIP40 front panel:· IP20 body:
Reference standardBS EN 61557-12
Net weight0.26 kg
BrandSchneider
Brand SKUMETSEPM3255
ELINEDH6RGHHDD
Sold asPer pc
Depth70 mm
RangePowerLogic
Width90 mm
Height95 mm
StandardsBS EN 61557-12 · IEC 61557-12 · EN 61557-12 · BS EN 61326-1 · IEC 61326-1 · EN 61326-1 · BS EN 62052-11 · IEC 62052-11 · EN 62052-11 · BS EN 62053-21 · IEC 62053-21 · EN 62053-21 · BS EN 62053-22 · IEC 62053-22 · EN 62052-22 · BS EN 62053-23 · IEC 62053-23 · EN 62052-23 · BS EN 61010-1 · EN 61010-1 · IEC 61010-1 · UL 61010-1 · BS EN 61010-2-30 · IEC 61010-2-30 · EN 61010-2-30 · UL 61010-2-30 · ANS
Display typeBacklit LCD
Product namePowerLogic PM3000
Mounting modeClip-on
Sampling rate32 samples/cycle
Accuracy classClass 0.5S active energy conforming to IEC 62053-22 · Class 1 active energy conforming to IEC 62053-21 · Class 2 reactive energy conforming to IEC 62053-23 · Class C active energy conforming to EN 50470-3
Data recordingEnergy consumption logs · 15 alarms · Power logs · Time stamping · Min/max of instantaneous values
Market segmentBuildings small building cost management: billing: sub feeder · Buildings medium building cost management: billing: sub feeder · Buildings large building cost management: billing: sub feeder · Buildings multi-site cost management: billing: sub feeder · Data center cost management: billing: sub feeder · Healthcare cost management: billing: sub feeder · Industry cost management: billing: sub feeder
supply voltage100...277 V AC 45...65 Hz · 173...480 V AC 45...65 Hz · 100...300 V DC
Memory capacity512 KB
type of network3P · 3P + N · 1P + N
Mounting supportDIN rail
Number of inputs2 digital 0...4 mA 11...40 V DC
Pollution degree2
Device short namePM3255
Network frequency60 Hz · 50 Hz
Number of outputs2 digital (static)
Relative humidity5…95 % at 50 °C
Device applicationMulti-tariff · Power monitoring · Sub billing
Display resolution128 x 96 pixels
Operating altitude< 3000 m
[In] rated current5 A · 1 A
Analogue input typeCurrent 0...5 A · Current 0...1 A
Measurement current0.02…1.2 A · 0.05…6 A
Measurement voltage50…330 V AC 45...65 Hz direct · 50…330 V AC 45...65 Hz phase to neutral · 80…570 V AC 45...65 Hz direct · 80…570 V AC 45...65 Hz phase to phase · 570…999000 V AC 45...65 Hz with external VT
Type of measurementActive and reactive power · Apparent power · Current · Voltage · Energy · Power factor · Frequency · Total current harmonic distortion THD (I) · Total voltage harmonic distortion THD (U)
Measurement accuracyCurrent 0.3 % 0.5...6 A · Current 0.5 % 0.1...1.2 A · Voltage 0.3 % 50...330 V · Voltage 0.3 % 80...570 V
Overvoltage categoryIII
Information displayedTariff (4)
Power quality analysisup to the 15th harmonic
Product certificationsCE conforming to IEC 61010-1 (safety) · CE conforming to EN 61557-12 (power monitor) · CE conforming to EN/IEC 61326-1 (EMC) · UKCA conforming to BS EN 61010-1 (safety) · UKCA conforming to BS EN 61557-12 (power monitor) · UKCA conforming to BS EN 61326-1 (EMC) · CULus conforming to EN 61010-1 (safety) · CULus conforming to UL 61010-1 (safety) · EAC (sub-meter) · RCM
IP degree of protectionIP40 front panel: conforming to IEC 60529 · IP20 body: conforming to IEC 60529
Power consumption in VA5 VA
Product or component typePower meter
Communication port supportRS485
Communication port protocolModbus at 9.6...38.4 kbauds
Frequency measurement range45…65 Hz
Electromagnetic compatibilityElectrostatic discharge level 4 conforming to IEC 61000-4-2 · Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 · Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 · Surge immunity test level 4 conforming to IEC 61000-4-5 · Conducted RF disturbances level 3 conforming to IEC 61000-4-6 · Magnetic field at power frequency - test level: 0.5 m
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…70 °C
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.