🚚 We deliver pan-India · GST invoice on every order · 30-day NBFC credit coming soon — join the waitlist →
Catalogue  /  Switchgear  /  Havells DP C MCB — 20 A
DHMXCDPZ02038% off MRP
BrandHavells
CategorySwitchgear
SpecificationCircuit Breaker · Type Double Pole · Curve C Curve · Rated Frequency 50 Hz · Dimensions 84 mm x 60.2 mm x 17.7 mm · Current Rating 10 A · Rated Current (6 A, 10 A, 16 A, 20 A, 25 A
SKUDHMXCDPZ020
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 3–7 working days
Havells· In stock

Havells DP C MCB — 20 A

Rating: 20 A
₹444/pc+ 18% GST
₹524 incl. GST · MRP ₹72238% off
Wholesale · 15+ units
₹422 +GST /pc
save 5%
1
+
Add to cart
Buy now
🚚 Delivered pan-India · 30-day NBFC credit is coming soon — join the waitlist.
₹444 /pc + GST
Free pan-India delivery
Price history
Elume price over time. Market comparison appears once we track this item. Updated regularly.
ElumeMRP
Elume today
₹524
MRP
₹852
1 price point
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
3–7 working days to any site in India
📦
Wholesale built in
−5% auto-applies at 15+ units — ₹498/pc on this product

About this product

from havells.com
  • IS/IEC 60898-1
  • Flame-Retardant Thermoplastic Material
  • Superior Air Circulation
  • Hammer Trip mechanism
  • Suitable for protection against overload & short circuit for Motor and other Inductive loads
  • Line & Load Interchangeability
  • Ease of Installation
As published by Havells. Verify critical parameters against the datasheet before specifying.

Technical specifications

Havells Havells DP C MCB — 20 A · DHMXCDPZ020
Device typeMiniature circuit breaker (MCB)
Current rating20 A
Poles2-pole (DP)
Reference standardIS/IEC 60898-1
BrandHavells
SKUDHMXCDPZ020
Sold asPer pc
TypeDouble Pole
CurveC Curve
Humidity95 % RH
Dimensions84 mm x 60.2 mm x 17.7 mm
Net Contents1 N Main Unit
Net Quantity1 N
No. of Poles1P, 1P+N, 2P, 3P+N, 4P
Product rangeCircuit Breaker
Rated Current(6 A, 10 A, 16 A, 20 A, 25 A, 32 A, 40 A, 63 A)
Type Or Series6 A - 63 A, C- Curve
Manufactured ByHavells India Ltd.
Rated Frequency50 Hz
Protection ClassIP20
Shock Resistance40 mm free fall
Country Of OriginIndia
Mounting Din Rail35 mm x 7.5 mm
Energy Limit Class3
Rated Voltage (Ue)240 V AC / 415 V AC
Installation PositionVertical / Horizontal
Operating Temperature-5 °C to 50 °C
Rated Impulse Voltage4 kV
Magnetic Release Setting( 5 - 10 ) In - C Curve
Rated Insulation Voltage690 V
Tightening Torque Capacity2 Nm
Terminal Capacity (Maximum)25 mm²
Rated Short Circuit Breaking Capacity6 kA
Electrical / Mechanical Endurance (No. of operations) Minimum10000 ≤ 32 A (No. of operations), 20000 > 32 A (No. of operations)

The full range · 7 options

Every option is its own product with live pricing — tap a row to switch.
OptionRatingElume price (ex-GST)MRPOff
Havells DP C MCB — 10 AParent10 A₹444₹72238%
Havells DP C MCB — 16 A16 A₹444₹72238%
Havells DP C MCB — 63 A63 A₹739₹1,20239%
Havells DP C MCB — 25 A25 A₹444₹72238%
Havells DP C MCB — 20 AViewing20 A₹444₹72238%
Havells DP C MCB — 32 A32 A₹444₹72238%
Havells DP C MCB — 40 A40 A₹625₹1,01639%

Know before you buy

Read: Top 10 MCBs & Switchgear in India (2026)
What is the difference between an MCB, an RCCB and an RCBO?
An MCB protects against overload and short circuit (overcurrent). An RCCB protects against earth leakage and electric shock by detecting current imbalance, typically at 30mA, but offers no overcurrent protection. An RCBO combines both functions in one module, giving overcurrent and earth-leakage protection per circuit, saving DIN-rail space.
Should I use a Type AC or Type A RCCB in India?
Type AC detects only AC earth leakage and suits basic resistive and inductive loads. Type A also detects pulsating DC leakage produced by electronics, EV chargers, inverters and LED drivers. Since most Indian homes now run such loads, Type A is the safer choice. Use Type B for solar inverters and variable-frequency drives.
What breaking capacity (kA) do I need for an Indian home?
Breaking capacity is the maximum fault current an MCB can safely interrupt. For most homes located some distance from the transformer, 6kA is adequate. For apartments, boards close to the distribution transformer, and commercial mains, specify 10kA or higher. Always base it on the actual prospective short-circuit current at your board.

Frequently asked questions

Is Havells DP C MCB — 20 A genuine and warranty-backed?

Yes. Every Havells product on Elume is 100% genuine, sourced through authorised channels, and carries the manufacturer's standard warranty.

Do you deliver across India?

Yes — we deliver pan-India, usually within 3–7 working days, and delivery is free.

Can I get a GST invoice?

Yes. Enter your GSTIN at checkout and we issue a GST invoice with tax shown separately, so businesses can claim input tax credit.

Is there a wholesale or bulk rate?

Yes. Orders of 15 or more pcs get a wholesale rate about 5% below the listed Elume price — shown on every product page.

What is the return policy?

Unused items in original packaging can be returned within 7 days of delivery, with free return shipping.

Verified reviews

No reviews yet