🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB S803S-K20 High Performance MCB · 2CCS863001R04872CCS863001R0487↓ 5% off MRP
BrandABB
CategorySwitchgear
SpecificationMCB · 3P+N · 20 A · K curve · 50 kA · Type Standard Version
Brand SKU2CCS863001R0487
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB S803S-K20 High Performance MCB · 2CCS863001R0487

₹8,376/pcincl. GST-5%
₹7,098 + 18% GST · MRP ₹8,795
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹8,376 /pc incl. GST
Free pan-India delivery

ABB S803S-K20 High Performance MCB · 2CCS863001R0487: Elume price today ₹8,376 per pc incl. GST, 5% below the ₹8,795 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹6,701, ₹1,675 less than here. The lowest tracked seller lists it at ₹6,701, ₹1,675 below it (tell us and we match it).

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹9,411₹8,585₹7,759₹6,933₹6,107₹8,795₹8,376₹6,701
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹8,376
Avg market price
₹6,701
MRP
₹8,795
Lowest in view · 10 Aug
₹6,567
Highest in view · 3 Oct
₹8,795
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
TP
20 A
-
50 kA
₹7,098 +GST /pc
₹8,376 incl. GST
Viewing above ↑
MCB
TP
20 A
-
-
₹1,208 +GST /pc
₹1,425 incl. GST
MCB
TP
20 A
C
-
₹1,554 +GST /pc
₹1,834 incl. GST
MCB
TP
20 A
D
-
₹1,603 +GST /pc
₹1,892 incl. GST
MCB
TP
20 A
C
-
₹1,847 +GST /pc
₹2,180 incl. GST
MCB
TP
20 A
C
-
₹2,027 +GST /pc
₹2,392 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹7,957/pc on this product, applied automatically

The S803S-K20 is a 3-pole High Performance Circuit breaker with K-Characteristic, with cage terminal and a rated current of 20 A. It is a current limiting device with a maximum breaking capacity of 50kA at 240/415V. It can be used for voltages up to 400/690V and in DC as well. It has two different tripping mechanisms, the thermal tripping mechanism for overload protection and the electromechanic t

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB S803S-K20 High Performance MCB · 2CCS863001R0487 · 2CCS863001R0487
Device typeMiniature circuit breaker (MCB)
SeriesS800S
Poles3P+N (TPN)
Rated current20 A
Trip curveK curve
Breaking capacity50 kA
RCCB typeType Standard Version
Rated voltageacc. to IEC 60898-1 400 V AC
Frequency50/60 Hz
Service breaking capacity (Ics)40 kA
ReleaseK
Insulation voltage (Ui)acc. to IEC/EN 60664-1 690 V
Impulse withstand (Uimp)8 kV
Width4.5 modules (81 mm)
Terminal capacityFlexible 0 … 50 mm²
Ingress protectionIP20
Reference standardIEC/EN 60947-2, IEC/EN 60898-1, UL 1077
Net weight0.735 kg
Country of originSwitzerland
Current rating20 A
BrandABB
Brand SKU2CCS863001R0487
ELINEDMK46JMJ7
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 9AKK108468A9560; shop.in.abb.com listing for 2CCS863001R0487, 23 Sep 2026; Product name). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.