Out of stock · 3 alternativesHoneywell · Impact MCB · 3P (TP) · 4 A · C curve · 10 kA · IH33P0C004₹1,642₹2,052
Orient Eurotech MCB Triple Pole · Curve C · 04 A101TPC0040↓ 22% off MRP
BrandOrient
CategorySwitchgear
Specification04 A · 3P
Brand SKU101TPC0040
AvailabilityOut of stock
DeliveryPan-India · 7 working days
Orient· Out of stock
Visit the Orient store

Orient Eurotech MCB Triple Pole · Curve C · 04 A

Rating: 04A
struck through = out of stock
₹1,585/pcincl. GST-22%
₹1,343 + 18% GST · MRP ₹2,020
Out of stock
This one cannot be ordered right now. These match its specification and are in stock:
Same specificationMCB · TP · 4 A
HoneywellIn stock
Impact MCB · 3P (TP) · 4 A · C curve · 10 kA · IH33P0C004
₹1,642incl. GST/pc-20%
MRP ₹2,052
ABBIn stock
SB200M MCB · 3P (TP) · 4 A · C curve · 10 kA · 1SYS273012R0044
₹1,671incl. GST/pc-53%
MRP ₹3,539
Lauritz KnudsenIn stock
Exora MCB · 3P (TP) · 4 A · C curve · 10 kA · BB30040C
₹1,872incl. GST/pc-35%
MRP ₹2,861
Compare all 18 in-stock alternatives ↓
Need this exact model? Email info@elumenuvo.com and we will source it for you.
💳 30 Day credit facility available launching soon - join waitlist.

Orient Eurotech MCB Triple Pole · Curve C · 04 A: Elume price today ₹1,585 per pc incl. GST, 22% below the ₹2,020 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
24 Aug to 22 Nov
₹2,269₹2,071₹1,872₹1,673₹1,474₹2,020₹1,585
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹1,585
MRP
₹2,020
Lowest in view · 22 Sep
₹1,585
Highest in view · 3 Oct
₹1,664
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
TP
4 A
-
-
₹1,343 +GST /pc
₹1,585 incl. GST
Viewing above ↑
MCB
TP
4 A
C
10 kA
₹1,392 +GST /pc
₹1,642 incl. GST
MCB
TP
4 A
C
10 kA
₹1,416 +GST /pc
₹1,671 incl. GST
MCB
TP
4 A
C
10 kA
₹1,586 +GST /pc
₹1,872 incl. GST
MCB
TP
4 A
D
10 kA
₹1,608 +GST /pc
₹1,898 incl. GST
MCB
TP
4 A
-
7.5 kA
₹1,737 +GST /pc
₹2,050 incl. GST
MCB
TP
4 A
C
-
₹1,918 +GST /pc
₹2,263 incl. GST
MCB
TP
4 A
D
-
₹1,957 +GST /pc
₹2,309 incl. GST
MCB
TP
4 A
C
10 kA
₹2,016 +GST /pc
₹2,379 incl. GST
MCB
TP
4 A
-
15 kA
₹2,072 +GST /pc
₹2,445 incl. GST
MCB
TP
4 A
-
15 kA
₹2,301 +GST /pc
₹2,715 incl. GST
MCB
TP
4 A
-
10 kA
₹2,325 +GST /pc
₹2,743 incl. GST
MCB
TP
4 A
-
15 kA
₹2,373 +GST /pc
₹2,800 incl. GST
MCB
TP
4 A
C
-
₹2,433 +GST /pc
₹2,871 incl. GST
MCB
TP
4 A
C
-
₹2,434 +GST /pc
₹2,872 incl. GST
MCB
TP
4 A
D
-
₹2,710 +GST /pc
₹3,198 incl. GST
MCB
TP
4 A
C
15 kA
₹2,726 +GST /pc
₹3,217 incl. GST
MCB
TP
4 A
D
15 kA
₹2,768 +GST /pc
₹3,266 incl. GST
MCB
TP
4 A
C
10 kA
₹4,569 +GST /pc
₹5,391 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹1,506/pc on this product, applied automatically

Orient Eurotech MCB Triple Pole is a switchgear product from Orient. Key ratings: rated current 04 A, poles 3P, trip curve C.

As published by Orient. Verify critical parameters against the datasheet before specifying.
Orient Orient Eurotech MCB Triple Pole · Curve C · 04 A · 101TPC0040
Poles3P (TP)
Rated current4 A
Trip curveC curve
Device typeMiniature circuit breaker (MCB)
Current rating04 A
Reference standardIS/IEC 60898-1
BrandOrient
Brand SKU101TPC0040
ELINERM996HFHJ
Sold asPer pc
Ratings as published by Orient (orientelectric.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What current is this MCB rated for and what wire should I use with it?

This MCB is rated 04A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet