🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand DX3 RCBO · 4P (FP) · 25 A · 300 mA · Type A · 6 kA · 411436411436↓ 38% off MRP1 / 3
BrandLegrand
CategorySwitchgear
SpecificationResidual current breaker with overload protection · 4P (FP) · 25 A · 300 mA · Type A · 6 kA · 4 M
Brand SKU411436
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Legrand· In stock
Visit the Legrand store

Legrand DX3 RCBO · 4P (FP) · 25 A · 300 mA · Type A · 6 kA · 411436

₹8,942/pcincl. GST-38%
₹7,578 + 18% GST · MRP ₹14,401
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹8,942 /pc incl. GST
Free pan-India delivery

Legrand DX3 RCBO · 4P (FP) · 25 A · 300 mA · Type A · 6 kA · 411436: Elume price today ₹8,942 per pc incl. GST, 38% below the ₹14,401 MRP. Today's price is the lowest of the last 30 days (high ₹8,943). The average price across the sellers we track is ₹7,226, ₹1,716 less than here. The lowest tracked seller lists it at ₹7,226, ₹1,716 below it (tell us and we match it).

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
24 Aug to 22 Nov
₹19,261₹16,109₹12,957₹9,805₹6,653₹14,401₹8,942₹7,226
24 Aug11 Sep29 Sep17 Oct4 Nov22 Nov
Elume today
₹8,942
Avg market price
₹7,226
MRP
₹14,401
Lowest in view · 7 Oct
₹7,154
Highest in view · 23 Oct
₹8,943
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCBO · Type A
4P / 3P+N (three phase)
25 A
-
300 mA
₹7,578 +GST /pc
₹8,942 incl. GST
Viewing above ↑
RCBO
4P / 3P+N (three phase)
25 A
-
300 mA
₹6,822 +GST /pc
₹8,050 incl. GST
RCBO
4P / 3P+N (three phase)
25 A
-
300 mA
₹8,162 +GST /pc
₹9,631 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹8,495/pc on this product, applied automatically

Legrand DX3-FP 4M A Type 25A 300MA 6KA RCBO

As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DX3 RCBO · 4P (FP) · 25 A · 300 mA · Type A · 6 kA · 411436 · 411436
Device typeResidual current breaker with overload protection (RCBO)
SeriesDX3
Poles4P (FP)
Rated current25 A
Breaking capacity6 kA
Sensitivity (IΔn)300 mA
RCCB typeType A
Warranty5 years if mounted inside Legrand DB
Country of originIndia
Module size4 M
Current rating25 A
Reference standardIS/IEC 60898-1
BrandLegrand
Brand SKU411436
ELINEMHRGR2G2G
Sold asPer pc
Product Code411436
Product features➥Conforms to IEC 60947➥Integrated label holder➥Ergonomic design➥Color coded On/Off indication on dolly➥Front face indication for earth leakage fault➥IP 20 protected terminals➥35 sq mm terminals➥Sliding shutters No. of Poles: 4P Closing and Opening (Trip free mechanism) IP 20 protected terminals Rated Voltage and Frequency:240/415 V~ . 50 Hz with standard tolerances
Mechanism / AccessoriesMechanism
Ratings as published by Legrand (shop.legrand.co.in). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
THIS UNIT
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between RCBO and RCCB?

An RCBO combines an MCB and an RCCB in one device, protecting a single circuit against overload, short circuit and earth leakage. An RCCB only handles earth leakage and needs separate MCBs (RCBOs are covered by IS 12640 (Part 2)).

Why use RCBOs instead of one main RCCB?

With RCBOs, a leakage fault on one circuit trips only that circuit, so the rest of the house keeps power and it is easier to find the fault. They cost more and take more DB space than one RCCB with several MCBs, so many homes use RCBOs only on critical circuits like geyser, washing machine and outdoor points.

Can I use an RCBO for my geyser or water pump?

Yes, an RCBO suits geysers, pumps and other loads in wet areas because it gives shock protection and overload protection on that one circuit. Choose the current rating and curve as you would for an MCB, based on the appliance's rated current and the cable, and have a licensed electrician confirm.

Does an RCBO need a neutral connection?

Yes. The RCBO compares phase and neutral current to detect leakage, so the circuit's neutral must pass through it and must not be shared with any other circuit.

Will an RCBO fit in a normal MCB distribution board?

RCBOs mount on the standard 35mm DIN rail, but many are 2 modules wide or need a separate neutral connection, so check that your DB has enough free ways and space. Some compact single-module RCBOs fit like an SP MCB; refer to the product's module width.

No reviews yet