🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Lauritz Knudsen DU250 MCCB · 3P (TP) · 250 A · 36 kA · Thermal-magnetic release · CM98060OOOOCM98060OOOO↓ 16% off MRP
BrandLauritz Knudsen
CategorySwitchgear
SpecificationMCCB · 3P (TP) · 250 A · 415 V AC
Brand SKUCM98060OOOO
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen DU250 MCCB · 3P (TP) · 250 A · 36 kA · Thermal-magnetic release · CM98060OOOO

Poles: 3 Pole
Current Rating: 250A
₹16,805/pcincl. GST-16%
₹14,242 + 18% GST · MRP ₹19,950
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹16,805 /pc incl. GST
Free pan-India delivery

Lauritz Knudsen DU250 MCCB · 3P (TP) · 250 A · 36 kA · Thermal-magnetic release · CM98060OOOO: Elume price today ₹16,805 per pc incl. GST, 16% below the ₹19,950 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
25 May to 22 Nov
₹21,347₹19,731₹18,116₹16,500₹14,885₹19,950₹16,805
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹16,805
MRP
₹19,950
Lowest in view · 17 Aug
₹16,005
Highest in view · 3 Oct
₹16,805
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
TP
250 A
-
36 kA
₹14,242 +GST /pc
₹16,805 incl. GST
Viewing above ↑
MCCB
TP
250 A
-
-
₹703 +GST /pc
₹829 incl. GST
MCCB
TP
250 A
-
-
₹1,239 +GST /pc
₹1,462 incl. GST
MCCB
TP
250 A
-
-
₹21,033 +GST /pc
₹24,819 incl. GST
MCCB
TP
250 A
-
36 kA
₹21,924 +GST /pc
₹25,870 incl. GST
MCCB
TP
250 A
-
36 kA
₹22,457 +GST /pc
₹26,499 incl. GST
MCCB
TP
250 A
-
36 kA
₹25,884 +GST /pc
₹30,543 incl. GST
MCCB
TP
250 A
-
36 kA
₹26,219 +GST /pc
₹30,938 incl. GST
MCCB
TP
250 A
-
36 kA
₹28,923 +GST /pc
₹34,129 incl. GST
MCCB
TP
250 A
-
36 kA
₹29,092 +GST /pc
₹34,329 incl. GST
MCCB
TP
250 A
-
36 kA
₹29,838 +GST /pc
₹35,209 incl. GST
MCCB
TP
250 A
-
36 kA
₹38,514 +GST /pc
₹45,446 incl. GST
MCCB
TP
250 A
-
36 kA
₹40,120 +GST /pc
₹47,342 incl. GST
MCCB
TP
250 A
-
36 kA
₹41,434 +GST /pc
₹48,892 incl. GST
MCCB
TP
250 A
-
36 kA
₹41,622 +GST /pc
₹49,114 incl. GST
MCCB
TP
250 A
-
36 kA
₹49,235 +GST /pc
₹58,097 incl. GST
MCCB
TP
250 A
-
36 kA
₹52,542 +GST /pc
₹62,000 incl. GST
MCCB
TP
250 A
-
36 kA
₹55,745 +GST /pc
₹65,779 incl. GST
MCCB
TP
250 A
-
36 kA
₹59,762 +GST /pc
₹70,519 incl. GST
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹15,965/pc on this product, applied automatically

Lauritz Knudsen DU250 MCCB · 3P (TP) · 250 A · 36 kA · Thermal-magnetic release is an MCCB from Lauritz Knudsen. Key ratings: Poles 3P (TP), Rated current 250 A, Breaking capacity 36 kA, Release Thermal-Magnetic, Rated voltage 415 V AC.

  • Phase barriers supplied with the breaker
  • Wide range of snap-fit internal and external accessories
  • Spreader terminals available for larger cables
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen DU250 MCCB · 3P (TP) · 250 A · 36 kA · Thermal-magnetic release · CM98060OOOO · CM98060OOOO
Device typeMoulded case circuit breaker (MCCB)
Poles3P (TP)
Rated current250 A
Breaking capacity36 kA
Rated voltage415 V AC
ReleaseThermal-Magnetic
Current rating250 A
Reference standardIS/IEC 60898-1
BrandLauritz Knudsen
Brand SKUCM98060OOOO
ELINEH9FFK3J24
Sold asPer pc
Ratings as published by Lauritz Knudsen (Elume catalogue; Product name; Lauritz Knudsen smartshop). Verify critical parameters against the datasheet before specifying.
Other Lauritz Knudsen ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Thermal-magnetic or microprocessor release - which one do I need?

The release type of this MCCB is Thermal-Magnetic. Thermal-magnetic releases are simpler and suit most feeders, while microprocessor (electronic) releases give finer adjustable settings, earth fault protection options and better selectivity for main incomers and critical loads.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet