🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand DPX³ 160 MCCB · 3P (TP) · 100 A · 36 kA · thermal magnetic · 420085420085↓ 26% off MRP
BrandLegrand
CategorySwitchgear
Specification3P · 100 A · 36 kA · thermal magnetic
Brand SKU420085
AvailabilityOn order · 2 to 3 weeks
DeliveryPan-India · 2 to 3 weeks
Legrand· On order, 2 to 3 weeks
Visit the Legrand store

Legrand DPX³ 160 MCCB · 3P (TP) · 100 A · 36 kA · thermal magnetic · 420085

NEW added this week
₹11,692/pcincl. GST-26%
₹9,908 + 18% GST · MRP ₹15,800
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Legrand for you once you place the order.
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹11,692 /pc incl. GST
Free pan-India delivery

Legrand DPX³ 160 MCCB · 3P (TP) · 100 A · 36 kA · thermal magnetic · 420085: Elume price today ₹11,692 per pc incl. GST, 26% below the ₹15,800 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹16,906₹15,398₹13,890₹12,382₹10,874₹15,800₹11,692
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹11,692
MRP
₹15,800
Lowest in view · 17 Nov
₹11,692
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
TP
100 A
-
36 kA
₹9,908 +GST /pc
₹11,692 incl. GST
Viewing above ↑
MCCB
TP
100 A
-
-
₹527 +GST /pc
₹622 incl. GST
MCCB
TP
100 A
-
36 kA
₹7,779 +GST /pc
₹9,179 incl. GST
MCCB
TP
100 A
-
-
₹8,139 +GST /pc
₹9,604 incl. GST
MCCB
TP
100 A
-
36 kA
₹9,219 +GST /pc
₹10,878 incl. GST
MCCB
TP
100 A
-
36 kA
₹9,336 +GST /pc
₹11,017 incl. GST
MCCB
TP
100 A
-
36 kA
₹11,016 +GST /pc
₹12,999 incl. GST
MCCB
TP
100 A
-
36 kA
₹12,097 +GST /pc
₹14,275 incl. GST
MCCB
TP
100 A
-
36 kA
₹14,488 +GST /pc
₹17,096 incl. GST
MCCB
TP
100 A
-
36 kA
₹16,982 +GST /pc
₹20,039 incl. GST
MCCB
TP
100 A
-
36 kA
₹22,278 +GST /pc
₹26,288 incl. GST
MCCB
TP
100 A
-
36 kA
₹24,784 +GST /pc
₹29,245 incl. GST
MCCB
TP
100 A
-
36 kA
₹26,101 +GST /pc
₹30,799 incl. GST
MCCB
TP
100 A
-
36 kA
₹30,541 +GST /pc
₹36,038 incl. GST
MCCB
TP
100 A
-
36 kA
₹30,723 +GST /pc
₹36,253 incl. GST
MCCB
TP
100 A
-
36 kA
₹43,415 +GST /pc
₹51,230 incl. GST
MCCB
TP
100 A
-
36 kA
₹47,316 +GST /pc
₹55,833 incl. GST
MCCB
TP
100 A
-
36 kA
₹54,293 +GST /pc
₹64,066 incl. GST
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹11,107/pc on this product, applied automatically

MCCB thermal magnetic - DPX³ 160 - Icu 36 kA - 400 V~ - 3P - 100 A. Breaking capacity of 36kA, according to EN/IEC standard 60947-2, suitable for protection of commercial and middle power installations - Compliant with NEMA AB‐1.

  • Rated insulation voltage of 800V - Rated impulse withstand voltage of 8kV.
  • Thermal protection with manual adjustment range of 0,8-1,0 of the rated current - Magnetic protection fixed at 10 time the rated current (minimum of 400A)
  • Supplied with fixing screws, cage terminals 70mm² maximum flexible cable or 95mm² maximum rigid cable - Can be fitted with other connection accessories: cage terminals, spreaders, rear terminals.
  • Can be equipped with auxiliaries (shunt release, undervoltage release, auxiliary contact), rotary handle, motor-driven handle and locking accessoryCan used with rotary handles or motor operator. Locking accessories are available.
As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DPX³ 160 MCCB · 3P (TP) · 100 A · 36 kA · thermal magnetic · 420085 · 420085
SeriesDPX³
Poles3P (TP)
Rated current100 A
Breaking capacity36 kA
Rated voltage400 V AC
Ultimate breaking capacity (Icu)36 kA
Insulation voltage (Ui)800 V
Impulse withstand (Uimp)8 kV
Warranty18 months from the date of shipment or 12 months from the date of installation
Device typeMiniature circuit breaker (MCB)
Current rating100 A
Reference standardIS/IEC 60898-1
BrandLegrand
Brand SKU420085
ELINEG2J2J7K33
Sold asPer pc
Ratings as published by Legrand (legrand.co.in; price list; Product title). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet