🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Honeywell Impact MCB · 2P (DP) · 25 A · D curve · 10 kA · IH32P0D025IH32P0D025↓ 20% off MRP
BrandHoneywell
CategorySwitchgear
Specification2P (DP) · 25 A · D curve · 10 kA
Brand SKUIH32P0D025
AvailabilityOn order · 2 to 3 weeks
DeliveryPan-India · 2 to 3 weeks
Honeywell· On order, 2 to 3 weeks
Visit the Honeywell store

Honeywell Impact MCB · 2P (DP) · 25 A · D curve · 10 kA · IH32P0D025

Rating: 25 A
Curve: D curve
Poles: 2P (DP)
NEW added this week
₹915/pcincl. GST-20%
₹775 + 18% GST · MRP ₹1,144
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Honeywell for you once you place the order.
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹915 /pc incl. GST
Free delivery over ₹4,000

Honeywell Impact MCB · 2P (DP) · 25 A · D curve · 10 kA · IH32P0D025: Elume price today ₹915 per pc incl. GST, 20% below the ₹1,144 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹1,224₹1,131₹1,038₹944₹851₹1,144₹915
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹915
MRP
₹1,144
Lowest in view · 17 Nov
₹915
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCB
DP
25 A
D
10 kA
₹775 +GST /pc
₹915 incl. GST
Viewing above ↑
MCB
DP
25 A
D
10 kA
₹743 +GST /pc
₹877 incl. GST
MCB
DP
25 A
-
-
₹760 +GST /pc
₹897 incl. GST
MCB
DP
25 A
D
10 kA
₹902 +GST /pc
₹1,064 incl. GST
MCB
DP
25 A
D
-
₹995 +GST /pc
₹1,174 incl. GST
MCB
DP
25 A
-
10 kA
₹1,031 +GST /pc
₹1,217 incl. GST
MCB
DP
25 A
D
-
₹1,168 +GST /pc
₹1,378 incl. GST
MCB
DP
25 A
D
10 kA
₹1,308 +GST /pc
₹1,543 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹897/pc on this product, applied automatically

Honeywell Impact MCB, 2P (DP), 25 A, D curve, 10 kA. Honeywell item code IH32P0D025.

  • 10kA Breaking Capacity
  • Air Vent Channels
  • 35sqmm Terminal Size
  • Bi-Connect Terminals
  • Line-Load Reversibility
  • Fast Trip Mechanism
As published by Honeywell. Verify critical parameters against the datasheet before specifying.
Honeywell Honeywell Impact MCB · 2P (DP) · 25 A · D curve · 10 kA · IH32P0D025 · IH32P0D025
SeriesImpact
Poles2P (DP)
Rated current25 A
Trip curveD curve
Breaking capacity10 kA
Device typeMiniature circuit breaker (MCB)
Current rating25 A
Reference standardIS/IEC 60898-1
BrandHoneywell
Brand SKUIH32P0D025
ELINED64G4FMMH
Sold asPer pc
Ratings as published by Honeywell (Honeywell price list). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

What curve is this MCB?

The tripping curve of this MCB is D curve. C is the general-purpose choice for mixed household loads, B suits lighting and resistive circuits, and D is for equipment with heavy inrush current.

What current is this MCB rated for and what wire should I use with it?

This MCB is rated 25 A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet