Lauritz Knudsen AU Changeover Switch · 3P (TP) · 32 A · 415 V AC · AUCL03032032AUCL03032032↓ 42% off MRP
BrandLauritz Knudsen
CategorySwitchgear
SpecificationChangeover Switch · 3P (TP) · 32 A · 415 V AC
Brand SKUAUCL03032032
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen AU Changeover Switch · 3P (TP) · 32 A · 415 V AC · AUCL03032032

Current Rating: 32A
₹13,416/pcincl. GST-42%
₹11,369 + 18% GST · MRP ₹23,200
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹13,416 /pc incl. GST
Free pan-India delivery

Lauritz Knudsen AU Changeover Switch · 3P (TP) · 32 A · 415 V AC · AUCL03032032: Elume price today ₹13,416 per pc incl. GST, 42% below the ₹23,200 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
25 May to 22 Nov
₹24,824₹21,589₹18,353₹15,118₹11,883₹23,200₹13,416
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹13,416
MRP
₹23,200
Lowest in view · 17 Aug
₹12,777
Highest in view · 3 Oct
₹13,416
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
CHANGEOVER
TP
32 A
n/a
-
₹11,369 +GST /pc
₹13,416 incl. GST
Viewing above ↑
CHANGEOVER
TP
32 A
n/a
-
₹5,205 +GST /pc
₹6,142 incl. GST
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹12,745/pc on this product, applied automatically

Lauritz Knudsen AU Changeover Switch · 3P (TP) · 32 A · 415 V AC is a changeover switch from Lauritz Knudsen. It transfers a load between two supplies, typically mains and generator, with a mechanical interlock so both are never connected at once. Key ratings: Poles 3P (TP), Rated current 32 A, Rated voltage 415 V AC, Phase Three phase. It is built to IEC 60947-6.

  • Mechanical interlock between the two supplies
  • Conforms to IEC 60947-3 and IS/IEC 60947-3
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen AU Changeover Switch · 3P (TP) · 32 A · 415 V AC · AUCL03032032 · AUCL03032032
Device typeChangeover switch
SeriesAU
Poles3P (TP)
Rated current32 A
Rated voltage415 V AC
Reference standardIEC 60947-6
PhaseThree phase
Current rating32 A
BrandLauritz Knudsen
Brand SKUAUCL03032032
ELINE9FD6FPDRD
Sold asPer pc
Ratings as published by Lauritz Knudsen (Lauritz Knudsen price list Aug 2026; Elume catalogue; Lauritz Knudsen smartshop; Product name). Verify critical parameters against the datasheet before specifying.
Other Lauritz Knudsen ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which changeover switch do I need for a generator at home?

Use a changeover switch rated at least equal to your main incomer, with poles matching the supply (2 pole for single-phase, 4 pole for three-phase) so the neutral is also switched. This prevents generator power feeding back into the grid, which is dangerous for line workers, and installation should be done by a licensed electrician.

What is the difference between on-load and off-load changeover?

An on-load changeover switch is designed to transfer between mains and generator while current is flowing, while an off-load type must only be operated after the load is switched off. On-load types are safer and more convenient for most homes and shops; check the load rating on the product.

What is the difference between manual changeover and ATS?

A manual changeover needs someone to operate the handle when power fails, while an ATS (automatic transfer switch) senses mains failure and switches to the generator automatically, often also starting the DG set. ATS is used where unattended or quick changeover is needed.

Why does a changeover switch have a centre OFF position?

The centre OFF position ensures the load is fully disconnected from both sources before connecting to the other, so mains and generator can never be connected together. It is also used to isolate the load safely for maintenance.

How many poles does this changeover switch have?

The pole configuration of this changeover switch is 3 Pole. For generator backup, switching the neutral as well (2 pole on single-phase, 4 pole on three-phase) is the usual recommended practice.

Can I use a changeover switch for an inverter?

Yes, a changeover switch is often used to select between inverter output and mains, or to bypass the inverter during servicing. Size it for the circuits it will carry and make sure inverter output and mains are never paralleled.