Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 100 mA · Type AC · BG204010BG204010↓ 35% off MRP
BrandLauritz Knudsen
CategorySwitchgear
SpecificationRCCB · 2P (DP) · 40 A · 100 mA · Type AC · 240 V AC · 2 M
Brand SKUBG204010
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 100 mA · Type AC · BG204010

Sensitivity: 100mA
Current Rating: 40A
₹3,647/pcincl. GST-35%
₹3,091 + 18% GST · MRP ₹5,623
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹3,647 /pc incl. GST
Free delivery over ₹4,000

Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 100 mA · Type AC · BG204010: Elume price today ₹3,647 per pc incl. GST, 35% below the ₹5,623 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
25 May to 22 Nov
₹6,017₹5,320₹4,623₹3,927₹3,230₹5,623₹3,647
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹3,647
MRP
₹5,623
Lowest in view · 17 Aug
₹3,473
Highest in view · 3 Oct
₹3,647
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹3,091 +GST /pc
₹3,647 incl. GST
Viewing above ↑
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹1,818 +GST /pc
₹2,145 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹1,879 +GST /pc
₹2,217 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹1,948 +GST /pc
₹2,299 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹1,981 +GST /pc
₹2,337 incl. GST
RCCB
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹2,723 +GST /pc
₹3,213 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹4,224 +GST /pc
₹4,984 incl. GST
RCCB
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹4,369 +GST /pc
₹5,156 incl. GST
RCCB · Type AC
2P / 1P+N (single phase)
40 A
n/a
100 mA
₹5,303 +GST /pc
₹6,257 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹3,465/pc on this product, applied automatically

Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 100 mA · Type AC is an RCCB from Lauritz Knudsen. It trips on earth-leakage current to protect people and wiring against electric shock and fire; it is fitted upstream of the MCBs it covers. Key ratings: Poles 2P (DP), Rated current 40 A, Sensitivity 100 mA, Type AC, Rated voltage 240 V AC, Width 2 M. It is built to IS 12640 (Part 1), IEC 61008-1.

  • Truly current operated: works even at reduced supply voltage
  • Core-balance current transformer (CBCT) sensing
  • Advanced neutral mechanism
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen Exora RCCB · 2P (DP) · 40 A · 100 mA · Type AC · BG204010 · BG204010
Device typeResidual current circuit breaker (RCCB)
SeriesEXORA
Poles2P (DP)
Rated current40 A
Sensitivity (IΔn)100 mA
RCCB typeType AC
Rated voltage240 V AC
Width2 modules
Reference standardIS 12640 (Part 1), IEC 61008-1
Current rating40 A
Sensitivity100 mA
BrandLauritz Knudsen
Brand SKUBG204010
ELINE3222J4RC4
Sold asPer pc
Ratings as published by Lauritz Knudsen (Elume catalogue; Lauritz Knudsen smartshop; Lauritz Knudsen price list Aug 2026; Product name). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
THIS UNIT
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

What sensitivity is this RCCB?

This RCCB trips at a residual (leakage) current of 100mA. 30mA is the standard for personal shock protection, while 100mA and 300mA are used for equipment and fire protection.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

Is this a 2 pole or 4 pole RCCB?

The pole configuration of this RCCB is 2 Pole. 2 pole is used on single-phase supply and 4 pole on three-phase supply with neutral, and the neutral of every protected circuit must pass through the same RCCB.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.

No reviews yet