🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand DPX³ 160 MCCB · 4P (FP) · 63 A · 16 kA · thermal magnetic with electronic earth leakage module · 420033420033↓ 26% off MRP
BrandLegrand
CategorySwitchgear
Specification4P · 63 A · 16 kA · thermal magnetic with electronic earth leakage module
Brand SKU420033
AvailabilityOn order · 2 to 3 weeks
DeliveryPan-India · 2 to 3 weeks
Legrand· On order, 2 to 3 weeks
Visit the Legrand store

Legrand DPX³ 160 MCCB · 4P (FP) · 63 A · 16 kA · thermal magnetic with electronic earth leakage module · 420033

NEW added this week
₹34,047/pcincl. GST-26%
₹28,853 + 18% GST · MRP ₹46,010
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Legrand for you once you place the order.
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹34,047 /pc incl. GST
Delivery ₹1,000, ships insured

Legrand DPX³ 160 MCCB · 4P (FP) · 63 A · 16 kA · thermal magnetic with electronic earth leakage module · 420033: Elume price today ₹34,047 per pc incl. GST, 26% below the ₹46,010 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹49,231₹44,839₹40,447₹36,055₹31,664₹46,010₹34,047
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹34,047
MRP
₹46,010
Lowest in view · 17 Nov
₹34,047
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
MCCB
FP (4 pole)
63 A
-
16 kA
₹28,853 +GST /pc
₹34,047 incl. GST
Viewing above ↑
MCCB
FP (4 pole)
63 A
-
16 kA
₹8,911 +GST /pc
₹10,515 incl. GST
MCCB
FP (4 pole)
63 A
-
-
₹9,219 +GST /pc
₹10,879 incl. GST
MCCB
FP (4 pole)
63 A
-
16 kA
₹15,639 +GST /pc
₹18,454 incl. GST
MCCB
FP (4 pole)
63 A
-
16 kA
₹16,005 +GST /pc
₹18,886 incl. GST
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹32,345/pc on this product, applied automatically

MCCB thermal magnetic with e.l.c.bs - DPX³ 160 - Icu 16 kA - 400 V~ - 4P - 63 A. Breaking capacity of 16kA, according to EN/IEC standard 60947-2, suitable for protection of commercial and middle power installations - Compliant with NEMA AB‐1.

  • Rated insulation voltage of 500V - Rated impulse withstand voltage of 6kV.
  • Thermal protection with manual adjustment range of 0,8-1,0 of the rated current - Magnetic protection fixed at 10 time the rated current (minimum of 400A)
  • Supplied with fixing screws, cage terminals 70mm² maximum flexible cable or 95mm² maximum rigid cable - Can be fitted with other connection accessories: cage terminals, spreaders, rear terminals.
  • Can be equipped with auxiliaries (shunt release, undervoltage release, auxiliary contact), rotary handle, motor-driven handle and locking accessoryCan used with rotary handles or motor operator. Locking accessories are available.
As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DPX³ 160 MCCB · 4P (FP) · 63 A · 16 kA · thermal magnetic with electronic earth leakage module · 420033 · 420033
SeriesDPX³
Poles4P (FP)
Rated current63 A
Breaking capacity16 kA
Rated voltage400 V AC
Ultimate breaking capacity (Icu)16 kA
Insulation voltage (Ui)500 V
Impulse withstand (Uimp)6 kV
Warranty18 months from the date of shipment or 12 months from the date of installation
Device typeMiniature circuit breaker (MCB)
Current rating63 A
Reference standardIS/IEC 60898-1
BrandLegrand
Brand SKU420033
ELINE2M99JG4P7
Sold asPer pc
Ratings as published by Legrand (legrand.co.in; price list; Product title). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.

No reviews yet