Rajdhani Ambition Tiny Trip MCB · 1P (SP) · 6 A · C curve: Elume price today ₹259 per pc incl. GST, 45% below the ₹471 MRP. The price has held steady for the last 30 days.
Rajdhani Ambition Tiny Trip miniature circuit breaker, 1P (SP), 6 A, C curve, 240 V AC 50 Hz, DIN-rail mount. Single-pole: it breaks the phase conductor of one circuit. C curve: trips instantly at 5 to 10 times the rated current, the general-purpose curve for lighting and socket circuits, and on a sustained overload above 6 A. 6 A suits a lighting circuit. One of the 6 to 32 A range in the Rajdhani Accessories List 2026 (w.e.f. 25 Apr 2026); sold per piece, the standard trade pack is 10. Photograph shows the Ambition Tiny Trip; the rating is printed on each unit.
Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.
The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.
This MCB is rated 6 A. As a rough guide for copper wiring in Indian homes, 6-10A usually goes with 1.5 sq mm lighting circuits, 16A with 2.5 sq mm socket circuits and 20-32A with 4-6 sq mm, but cable length and installation method matter, so have a licensed electrician confirm.
A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.
Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.
Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.
No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.