Havells Type 1+2 AC Surge Protection Device · 1P+N · DHSAARAC50320

⚡ Ranked #5 in Surge Protection for Rooftop Solar: AC vs DC SPD, Type 1 vs Type 2, and Which Brand to Choose · Rural overhead feeds, LPS buildings →
$93.21/pc-48%
$179.33
Out of stock

We list this so you can see the spec and our price, but it cannot be ordered right now. Email info@elumenuvo.com and we will source it for you.

🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $88.55/pc on this product, applied automatically

SP+N

  • High Discharge Current : Imax 50 kA (L – N)70 kA (N – E)
  • Compact Size : Integrated Type-1 & Type-2 protection in small module width. Ideal in all reduced-size plants.
  • Better Protection : Voltage protection level 1.5 kV
Pluggable Cartridges
•Faulty cartridges can be replaced without changing the entire SPD. • Cartridges can be replaced with mains voltage ON. • All cartridges are marked with characteristics for ease of maintenance.
Dedicated Protection of the Neutral
•The 1P+N and 3P+N SPDs with dedicated protection of the neutral pole discharge the common and differential mode overvoltages that may occur in installations with TT and TNS systems, when there is a voltage surge.
Remote Signaling Contact
• Option to remotely monitor the status of the surge protector. • Simplified cabling thanks to a single terminal for monitoring all poles.
End of Life Indicator
Finger Touch- Proof
• Terminal - IP 20
Simple, professional installation of arrester modules
• Mechanically coded cartridges to avoid cartridge replacement errors.
High Terminal Capacity
• 35 sq. mm Terminals
Ease of Installation
• Dual position of Din-rail clip.
As published by Havells. Verify critical parameters against the datasheet before specifying.
Havells Havells Type 1+2 AC Surge Protection Device · 1P+N · DHSAARAC50320 · DHSAARAC50320
Device typeSurge protection device (SPD)
SeriesSTADx
Poles1P+N (SPN)
SPD typeType 1+2
Max continuous operating voltage (Uc)320 V
Nominal discharge current (In)20 kA
Max discharge current (Imax)50 kA
Impulse current (Iimp)12.5 kA
Voltage protection level (Up)1.5 kV
Remote signalling contactYes
Country of originChina
Breaking capacity20 kA
Reference standardIS/IEC 60898-1
BrandHavells
Brand SKUDHSAARAC50320
ELINEJ7DHDHP49
Sold asPer pc
Imported ByHavells India Ltd.
Ratings as published by Havells (Havells STADx price list, Mar 2026; havells.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

How many poles do I need for my supply?

The pole configuration of this SPD is SP+N. A single-phase home typically uses a 1P+N or 2P SPD, and a three-phase supply uses 3P+N or 4P, so all live conductors are protected.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.

No reviews yet