🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider Harmony Timer RE22 Timing Relay · Off-delay without auxiliary supply · 0.05 s-10 min · 1 C/O · IP40 · RE22R1KMRRE22R1KMR↓ 40% off1 / 11
BrandSchneider
CategoryIndustrial Control
Specification1 C/O timed contact, cadmium free
Brand SKURE22R1KMR
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Harmony Timer RE22 Timing Relay · Off-delay without auxiliary supply · 0.05 s-10 min · 1 C/O · IP40 · RE22R1KMR

$156.50/pc-40%
$260.84
Wholesale · 15+ units
$148.69 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$156.50 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $148.69/pc on this product, applied automatically

This Harmony RE22 modular single function timer can be set between 1 seconds and 300 hours, has an output rating of 5 amperes and it is 22.5 millimeters wide. This modular single function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. Single function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Harmony Timer RE22 Timing Relay · Off-delay without auxiliary supply · 0.05 s-10 min · 1 C/O · IP40 · RE22R1KMR · RE22R1KMR
Ingress protectionIP40 housing:· IP50 front face:· IP20 terminals:
Reference standardIEC 61812-1
Net weight0.1 kg
BrandSchneider
Brand SKURE22R1KMR
ELINERPJ7FCGKG
Sold asPer pc
Width22.5 mm
Contacts1 C/O
Functionoff-delay without auxiliary supply
StandardsIEC 61812-1 · UL 508
Status LEDLED backlight green (steady) for dial pointer indication · LED yellow (steady) for output relay energised · LED yellow (steady) for power ON
Time range0.05 s-10 min
Control typeRotary knob
Recovery time100 ms on de-energisation
Voltage drift+/- 0.2 %/V
Voltage range0.85...1.1 Us
Power on delay350 ms
Repeat accuracy+/- 0.5 % conforming to IEC 61812-1
Time delay typeDelay on de-energization
Housing materialPolycarbonate
Mounting support35 mm DIN rail conforming to IEC 60715
Range of productHarmony Timer Relays
Supply frequency50...60 Hz +/- 5 %
Time delay range10...100 s · 1...10 min · 1...10 s · 0.3...3 s · 3...30 s · 0.05...1 s · 30...300 s
Creepage distance4 kV/3 conforming to IEC 60664-1
Device short nameRE22
Mounting positionAny position
Temperature drift+/- 0.05 %/°C
Tightening torque0.6…1 N.m conforming to IEC 60947-1
Function availableK-Delay on de-energization (without auxiliary supply)-1 C/O
Dielectric strength2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
Number of functions1
Discrete output typeRelay
Overvoltage categoryIII conforming to IEC 60664-1
Electrical durability100000 cycles, 2 A at 24 V, DC-1 · 100000 cycles, 5 A at 250 V, AC-1
Insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
Mechanical durability10000000 cycles
Release input voltage<= 2.4 V
Power consumption in W2 W at 240 V DC
nominal output current5 A
Connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (20 AWG...12 AWG) solid without cable end · Screw terminals, 2 x 0.5...2 x 2.5 mm² (20 AWG...14 AWG) solid without cable end · Screw terminals, 1 x 0.2...1 x 2.5 mm² (24 AWG...14 AWG) flexible with cable end · Screw terminals, 2 x 0.2...2 x 1.5 mm² (24 AWG...16 AWG) flexible with cable end
Immunity to microbreaks10 ms
Power consumption in VA3 VA at 240 V AC
Safety reliability dataMTTFd = 194 years · B10d = 180000
Switching capacity in VA1250 VA
Maximum switching current5 A
Maximum switching voltage250 V AC
Minimum switching current10 mA at 5 V DC
Product or component typeModular timing relay
[Us] rated supply voltage24...240 V AC/DC 50/60 Hz
Contacts type and composition1 C/O timed contact, cadmium free
Setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Rated impulse withstand voltage5 kV for 1.2…50 µs conforming to IEC 60664-1
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
What is the difference between on-delay and off-delay timers?

An on-delay timer switches its output after the set time once it receives power or a start signal, while an off-delay timer holds its output on for the set time after the signal is removed. Multifunction timers offer both and other modes such as cyclic and interval.

Which timer do I need for a star-delta starter?

A dedicated star-delta timer has a built-in short dead time between star and delta changeover to prevent a short circuit across contactors. The star time is set to suit how fast the motor reaches near full speed, often a few seconds to around 15 seconds.

What does a phase failure relay protect against?

A phase monitoring relay detects phase loss, phase reversal (wrong sequence) and often phase unbalance or under/over voltage, and trips the contactor coil to protect three-phase motors. It is especially useful for pumps, compressors and lifts where wrong rotation or single phasing can cause damage.

Can I use a timer to run a water pump automatically?

A cyclic or programmable timer can switch a pump contactor on and off at set intervals, but for tank level control a level controller relay with probes or a float switch is more reliable. The pump also needs proper motor protection like an MPCB or overload relay.

Do these mount on DIN rail?

Most modern timers and monitoring relays are DIN rail mounted (35mm), while some older or plug-in types use an 8-pin or 11-pin socket base. Check the mounting type and whether the base is included.

No reviews yet