Schneider Acti9 DPN Vigi RCBO · 1P+N · 20 A · 300 mA · C curve · A9N19686A9N19686↓ 40% off
BrandSchneider
CategorySwitchgear
Specification1P+N · 20 A · 300 mA · C curve
Brand SKUA9N19686
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 DPN Vigi RCBO · 1P+N · 20 A · 300 mA · C curve · A9N19686

Rating: 20 A
Sensitivity: 300 mA
$112.24/pc-40%
$187.06
Wholesale · 15+ units
$106.63 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$112.24 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCBO
2P / 1P+N (single phase)
20 A
C
300 mA
$112.24 /pc
Viewing above ↑
RCBO · Type AC
2P / 1P+N (single phase)
20 A
C
300 mA
$64.22 /pc
RCBO · Type AC
2P / 1P+N (single phase)
20 A
C
300 mA
$64.25 /pc
RCBO · Type AC
2P / 1P+N (single phase)
20 A
C
300 mA
$66.00 /pc
RCBO · Type AC
2P / 1P+N (single phase)
20 A
C
300 mA
$73.28 /pc
RCBO · Type A
2P / 1P+N (single phase)
20 A
C
300 mA
$109.46 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $106.63/pc on this product, applied automatically

Schneider Acti9 DPN Vigi RCBO · 1P+N · 20 A · 300 mA · C curve from Schneider Electric.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 DPN Vigi RCBO · 1P+N · 20 A · 300 mA · C curve · A9N19686 · A9N19686
Poles1P+N (SPN)
Rated current20 A
Trip curveC curve
Sensitivity (IΔn)300 mA
Reference standardEN/IEC 61009-2-1
Net weight0.19 kg
ColourWhite
Device typeMiniature circuit breaker (MCB)
Current rating20 A
BrandSchneider
Brand SKUA9N19686
ELINERPHRJ6PM7
Sold asPer pc
typeType AC
RangeActi9
StandardsEN/IEC 61009-2-1 · EN/IEC 61009-1
Curve codeC
9 mm pitches4
Control typeToggle
Network typeAC
Product nameDPN Vigi
Tropicalisation2 conforming to EN 61009
Limitation class3 conforming to EN 61009
Local signallingON/OFF indication
Mounting supportDIN rail
Neutral positionLeft
Pollution degree3 conforming to EN 61009
Breaking capacity6000 A Icn at 230 V AC conforming to EN 61009
Device short nameDPN N Vigi
Poles description1P + N
Relative humidity95 % at 55 °C
Operating altitude2000 m
[In] rated current20 A at 30 °C
Overvoltage categoryIII
Trip unit technologyThermal-magnetic
Electrical durability20000 cycles conforming to IEC 61009
Mechanical durability20000 cycles
Connections - terminalsTunnel type terminals1 cable(s) 10 mm² flexible · Tunnel type terminals1 cable(s) 16 mm² rigid
Magnetic tripping limit5...10 x In
Earth-leakage protectionIntegrated
Device location in systemOutgoer
Earth-leakage sensitivity300 mA
Number of protected poles1
Product or component typeEarth leakage circuit breaker
Contact position indicatorYes
Circuit breaker applicationDistribution
[Ui] rated insulation voltage400 V AC conforming to EN 61009
[Ue] rated operational voltage230 V AC
Ambient air temperature for storage-40…60 °C
Earth-leakage protection time delayInstantaneous
Residual current tripping technologyVoltage independent
Ambient air temperature for operation-5…60 °C
[Ics] rated service breaking capacity6000 A at 230 V AC 50/60 Hz conforming to EN 61009
[Uimp] rated impulse withstand voltage4 kV conforming to EN 61009
Ratings as published by Schneider (se.com; Schneider spec table). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between RCBO and RCCB?

An RCBO combines an MCB and an RCCB in one device, protecting a single circuit against overload, short circuit and earth leakage. An RCCB only handles earth leakage and needs separate MCBs (RCBOs are covered by IS 12640 (Part 2)).

Why use RCBOs instead of one main RCCB?

With RCBOs, a leakage fault on one circuit trips only that circuit, so the rest of the house keeps power and it is easier to find the fault. They cost more and take more DB space than one RCCB with several MCBs, so many homes use RCBOs only on critical circuits like geyser, washing machine and outdoor points.

What is the sensitivity of this RCBO?

This RCBO trips on leakage at 300 mA, in addition to normal overload and short-circuit protection. 30mA is the usual choice for shock protection on final circuits.

Can I use an RCBO for my geyser or water pump?

Yes, an RCBO suits geysers, pumps and other loads in wet areas because it gives shock protection and overload protection on that one circuit. Choose the current rating and curve as you would for an MCB, based on the appliance's rated current and the cable, and have a licensed electrician confirm.

Does an RCBO need a neutral connection?

Yes. The RCBO compares phase and neutral current to detect leakage, so the circuit's neutral must pass through it and must not be shared with any other circuit.

Will an RCBO fit in a normal MCB distribution board?

RCBOs mount on the standard 35mm DIN rail, but many are 2 modules wide or need a separate neutral connection, so check that your DB has enough free ways and space. Some compact single-module RCBOs fit like an SP MCB; refer to the product's module width.

No reviews yet