Lauritz Knudsen AU Standard RCCB · 2P (DP) · 25 A · 100 mA · Type Adi · AURAD202510AURAD202510↓ 36% off
BrandLauritz Knudsen
CategorySwitchgear
SpecificationRCCB · 2P (DP) · 25 A · 100 mA · Type Adi (AC + pulsating DC + harmonics) · 240 V · 2 M
Brand SKUAURAD202510
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Lauritz Knudsen· In stock
Visit the Lauritz Knudsen store

Lauritz Knudsen AU Standard RCCB · 2P (DP) · 25 A · 100 mA · Type Adi · AURAD202510

Sensitivity: 100mA
Current Rating: 25A
$81.38/pc-36%
$126.67
Wholesale · 15+ units
$77.32 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$81.38 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
100 mA
$81.38 /pc
Viewing above ↑
RCCB
2P / 1P+N (single phase)
25 A
n/a
100 mA
$43.21 /pc
RCCB
2P / 1P+N (single phase)
25 A
n/a
100 mA
$64.82 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
100 mA
$92.77 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
100 mA
$127.40 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $77.32/pc on this product, applied automatically

Lauritz Knudsen AU Standard RCCB · 2P (DP) · 25 A · 100 mA · Type Adi is an RCCB from Lauritz Knudsen. It trips on earth-leakage current to protect people and wiring against electric shock and fire; it is fitted upstream of the MCBs it covers. Key ratings: Poles 2P (DP), Rated current 25 A, Sensitivity 100 mA, Type Adi (AC + pulsating DC + harmonics), Rated voltage 240 V, Width 2 M. It is built to IS 12640 (Part 1), IEC 61008-1.

  • Truly current operated: works even at reduced supply voltage
  • Core-balance current transformer (CBCT) sensing
  • Advanced neutral mechanism
As published by Lauritz Knudsen. Verify critical parameters against the datasheet before specifying.
Lauritz Knudsen Lauritz Knudsen AU Standard RCCB · 2P (DP) · 25 A · 100 mA · Type Adi · AURAD202510 · AURAD202510
Device typeResidual current circuit breaker (RCCB)
SeriesAU
Poles2P (DP)
Rated current25 A
Sensitivity (IΔn)100 mA
RCCB typeType Adi (AC + pulsating DC + harmonics)
Rated voltage240 V
Width2 modules
Reference standardIS 12640 (Part 1), IEC 61008-1
Current rating25 A
Sensitivity100 mA
BrandLauritz Knudsen
Brand SKUAURAD202510
ELINER2CC9K6R7
Sold asPer pc
Ratings as published by Lauritz Knudsen (Elume catalogue; Lauritz Knudsen smartshop; Lauritz Knudsen price list Aug 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

What sensitivity is this RCCB?

This RCCB trips at a residual (leakage) current of 100mA. 30mA is the standard for personal shock protection, while 100mA and 300mA are used for equipment and fire protection.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

Is this a 2 pole or 4 pole RCCB?

The pole configuration of this RCCB is 2 Pole. 2 pole is used on single-phase supply and 4 pole on three-phase supply with neutral, and the neutral of every protected circuit must pass through the same RCCB.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.

No reviews yet