Honeywell Impact RCCB · 2P (DP) · 25 A · 100 mA · IH3R225100: Elume price today ₹2,976 per pc incl. GST, 20% below the ₹3,720 MRP. The price has held steady for the last 30 days.
Honeywell Impact RCCB, 2P (DP), 25 A, 100 mA. Honeywell item code IH3R225100.
For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.
This RCCB trips at a residual (leakage) current of 100 mA. 30mA is the standard for personal shock protection, while 100mA and 300mA are used for equipment and fire protection.
Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).
Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.
Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.
The pole configuration of this RCCB is 2P (DP). 2 pole is used on single-phase supply and 4 pole on three-phase supply with neutral, and the neutral of every protected circuit must pass through the same RCCB.
Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.
The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.