Schneider EasyPact CVS100NA Switch Disconnector · 4 poles · 100 A · AC22 A · AC23 A · LV510426LV510426↓ 40% off1 / 5
BrandSchneider
CategorySwitchgear
Specification4 poles · 100 A · AC22 A · AC23 A
Brand SKULV510426
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider EasyPact CVS100NA Switch Disconnector · 4 poles · 100 A · AC22 A · AC23 A · LV510426

$185.00/pc-40%
$308.34
Wholesale · 15+ units
$175.75 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$185.00 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $175.75/pc on this product, applied automatically

This EasyPact CVS100NA is a complete 4 poles switch disconnector. It is used to control and isolate electrical distribution circuits and it requires an upstream protection. The operational current is 100A at 415VAC 50/60Hz for AC22A and AC23A utilisation categories. The operational voltage is 440VAC 50/60Hz. It comes with a variety of optional functions and accessories common with EasyPact CVS circuit breakers. The dimensions for this 4 poles version are 140mm x 161mm x 86mm. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider EasyPact CVS100NA Switch Disconnector · 4 poles · 100 A · AC22 A · AC23 A · LV510426 · LV510426
Poles4P (FP)
Rated current22 A
Reference standardEN 60947-3
Net weight2.4 kg
Device typeSwitch disconnector (isolator)
Current rating100 A
BrandSchneider
Brand SKULV510426
ELINEMM7C2DK32
Sold asPer pc
Depth86 mm
RangeEasyPact
Width140 mm
Height161 mm
StandardsEN 60947-3 · IEC 60947-3
Control typeToggle
Network typeAC
Product nameEasyPact CVS
Mounting modeFixed
Visible breakNo
Connection pitch35 mm
Mounting supportBackplate
Pollution degree3 conforming to IEC 60664-1
Range of productEasyPact CVS100...250
Device short nameCVS100NA
Network frequency50/60 Hz
Poles description4P
Upside connectionFront
Device applicationDistribution
Downside connectionFront
Utilisation categoryAC-23A · AC-22A
Electrical durabilityAC-22A: 8000 cycles 415 V AC 50/60 Hz In conforming to IEC 60947-3 · AC-23A: 8000 cycles 415 V AC 50/60 Hz In conforming to IEC 60947-3
Mechanical durability30000 cycles conforming to IEC 60947-3
Breaking capacity codeNA
Product certificationsGOST · IEC
Earth-leakage protectionWithout
Product or component typeSwitch disconnector
Suitability for isolationYes conforming to EN 60947-3 · Yes conforming to IEC 60947-3
Contact position indicatorYes
[Ie] rated operational currentAC-22A: 100 A AC 50/60 Hz 220/240 V · AC-22A: 100 A AC 50/60 Hz 380/415 V · AC-22A: 100 A AC 50/60 Hz 440 V · AC-23A: 100 A AC 50/60 Hz 220/240 V · AC-23A: 100 A AC 50/60 Hz 380/415 V · AC-23A: 100 A AC 50/60 Hz 440 V
Electrical shock protection classClass II
Ambient air temperature for storage-50…85 °C
Ambient air temperature for operation-25…70 °C
[Icw] rated short-time withstand current0.69 kA during 20 s conforming to IEC 60947-3 · 1.8 kA during 1 s conforming to IEC 60947-3 · 1.8 kA during 3 s conforming to IEC 60947-3
[Icm] rated short-circuit making capacity75 kA with upstream protection circuit breaker · 2.6 kA switch-disconnector alone
[Ith] conventional free air thermal current100 A at 50 °C
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.