Schneider Acti9 iPRI SPD · A9L16339A9L16339↓ 40% off
BrandSchneider
CategorySwitchgear
SpecificationiPRI signal protection - 4 poles - 0.3A - 48 V
Brand SKUA9L16339
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 iPRI SPD · A9L16339

$262.04/pc-40%
$436.71
Wholesale · 15+ units
$248.94 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$262.04 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $248.94/pc on this product, applied automatically

This Acti9 iPRI is a surge arrester protecting against overvoltage related to lightning strikes. It is an analogue telephone line protection. The iPRC surge arrester wired in series to the private installation input protects telephones, modems. The Uc maximum continuous operating voltage in common mode (between phase and earth) is 37 VAC or 53VDC. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 37VAC or 53VDC. The Up Voltage protection level is 70V in differential mode (between phase and neutral) and in common mode (between phase and earth). The Ue rated operational voltage is 48VDC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 18mm x (H) 90mm x (D) 66mm. The weight is 65g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 iPRI SPD · A9L16339 · A9L16339
Rated current0.3 A
Ingress protectionIP40 (modular enclosure)· IP20
Reference standardIEC 61643-21
Net weight0.065 kg
ColourWhite
Device typeMiniature circuit breaker (MCB)
Current rating3 A
BrandSchneider
Brand SKUA9L16339
ELINEJHMJH33RK
Sold asPer pc
Depth66 mm
Width18 mm
Height90 mm
MaterialPA6
StandardsIEC 61643-21 · EN 61643-21
9 mm pitches2
Product nameActi9 iPRI
Mounting modeFixed
Response time< 1 ns
Local signallingelectrical
Mounting support35 mm symmetrical DIN rail
range of productActi9
Device short nameiPRI
Relative humidity5…90 %
Remote signallingWithout
Tightening torque0.8 N.m
Operating altitude2000 m
[In] rated current0.3 A at 45 °C
Surge arrester typeSignal protection
Output voltage limitsCommon mode: < 70 V at 1 kV/µs
Wire stripping length8 mm
[Iimp] impulse current70 A
Connections - terminalsScrew clamp terminal0.2…4 mm² rigid · Screw clamp terminal0.2…2.5 mm² flexible · Screw clamp terminal0.2…2.5 mm² flexible with ferrule
IK degree of protectionIK05 conforming to IEC 62262
IP degree of protectionIP40 (modular enclosure) conforming to IEC 60529 · IP20 conforming to IEC 60529
Nominal discharge currentCommon mode: 20 kA (L/PE)
Number of protected lines4
Product or component typeSurge arrester
Surge arrester technologyGDT
[I total] discharge current20 kA
[Ue] rated operational voltage48 V DC
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…60 °C
Maximum [Up] voltage protection levelCommon mode 70 V type 2 L/PE · Differential mode 70 V type 2 L/N
[Uc] maximum continuous operating voltageCommon mode: 37 V AC L/PE · Common mode: 53 V DC L/PE · Differential mode: 37 V AC L/N · Differential mode: 53 V DC L/N
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which type of SPD should I use for my home - Type 1 or Type 2?

For most homes and apartments, a Type 2 SPD in the main DB is the standard choice. Type 1 or combined Type 1+2 is used at the service entrance of independent houses in lightning-prone areas or buildings with external lightning protection (SPDs are covered by IS 16463 (Part 11), identical to IEC 61643-11).

Does an SPD need earthing?

Yes. An SPD diverts surge energy to earth, so it works only with a proper, low-resistance earth connection kept as short as possible. Without good earthing it gives little or no protection.

Will an SPD protect against high voltage from neutral failure?

No. SPDs are designed for short transient surges from lightning and switching, not sustained overvoltage such as from a broken neutral or poor supply. For that, use a voltage protection relay, an over/under voltage protector or stabilisers for sensitive equipment.

How do I know when the SPD needs replacing?

Most SPDs have an indicator window that turns from green to red when the protective element has reached end of life. Pluggable SPDs allow replacing only the cartridge; check the indicator periodically and after major thunderstorms.

Does an SPD need an MCB or fuse before it?

Yes, an SPD should have backup protection (MCB or fuse) as specified by the manufacturer, so a failed SPD can be safely disconnected without tripping the whole installation. The backup rating is usually listed in the SPD datasheet.

What do Imax, In and Up mean on an SPD?

Imax is the maximum surge current it can discharge once, In is the nominal current it can handle repeatedly, and Up is the voltage protection level (the let-through voltage), where lower is better. For 230 V homes, a Type 2 SPD with Imax around 40kA and a maximum continuous operating voltage (Uc) of 275 V or more is commonly used.