Schneider Acti9 iCT Power Contactor · 63 A AC-3 · 3 NO aux · 220-240 V AC 50 Hz coil · A9C20863A9C20863↓ 40% off1 / 2
BrandSchneider
CategorySwitchgear
Specification63 A AC-3 · 3 NO aux · 220...240 V AC 50 Hz coil
Brand SKUA9C20863
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider Acti9 iCT Power Contactor · 63 A AC-3 · 3 NO aux · 220-240 V AC 50 Hz coil · A9C20863

$141.07/pc-40%
$235.13
Wholesale · 15+ units
$134.02 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$141.07 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $134.02/pc on this product, applied automatically

This Acti9 iCT is a modular contactor. It is a 3P remote control device with 3 normally open contacts. The rated current is 63A for AC-7a and 20A for AC-7b. The Ue rated operational voltage is 400VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B. The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 6 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 85mm x (H) 54mm x (D) 68.5mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider Acti9 iCT Power Contactor · 63 A AC-3 · 3 NO aux · 220-240 V AC 50 Hz coil · A9C20863 · A9C20863
Poles3P (TP)
Rated current63 A
Ingress protectionIP20· IP40 (modular enclosure)
Reference standardIEC/EN 61095
coil voltage220...240 V AC 50 Hz
ColourWhite
Device typeMiniature circuit breaker (MCB)
Current rating63 A
BrandSchneider
Brand SKUA9C20863
ELINEJ799DPCR4
Sold asPer pc
Depth68.5 mm
Width54 mm
Height85 mm
StandardsIEC/EN 61095
Noise level30 dB
9 mm pitches6
Control typeRemote control
Network typeAC
Product nameActi9 iCT
Maximum power2.1 W at 400 V AC
Mounting modeClip-on
Market segmentSmall commercial · Residential
Tropicalisation2 conforming to EN 60947-4-1 · 2 conforming to EN 61095 · 2 conforming to IEC 1095
Local signallingAction indicator
Mounting support35 mm symmetrical DIN rail
Pollution degree2
range of productActi9
Device short nameiCT
Network frequency50 Hz
Relative humidity95 % at 55 °C
Tightening torqueControl circuit: 0.8 N.m · Power circuit: 3.5 N.m
Compatibility codeICT
Device applicationMotor-heating-lighting
Inrush power in VA53 VA
Operating altitude2000 m
Control signal typeMaintained
Switching frequency100 switching operations/day
Electrical durability100000 cycles IEC/EN 61095 63 A 50 Hz AC-7A · 30000 cycles IEC/EN 61095 20 A 50 Hz AC-7B · 30000 cycles IEC/EN 61095 50 Hz AC-7C
Mechanical durability1000000 cycles
Product compatibilityIACTc · IACTp · IACTs · IATEt
Connections - terminalsControl circuit: tunnel type terminals2 cable(s) 1.5 mm² rigid · Control circuit: tunnel type terminals1 cable(s) 1.5…2.5 mm² rigid · Power circuit: tunnel type terminals1 cable(s) 6…16 mm² flexible · Power circuit: tunnel type terminals1 cable(s) 6…25 mm² rigid · Control circuit: tunnel type terminals2 cable(s) 1.5…2.5 mm² flexible
IP degree of protectionIP20 conforming to IEC 60529 · IP40 (modular enclosure) conforming to IEC 60529
Pole contact composition3 NO
Product or component typeContactor
[Uc] control circuit voltage220...240 V AC 50 Hz
[Ui] rated insulation voltage500 V AC 50/60 Hz
[Ie] rated operational current63 A AC-7A · 20 A AC-7B
[Ue] rated operational voltage400 V AC 50 Hz
Hold-in power consumption in VA6.5 VA
Ambient air temperature for storage-40…70 °C
Ambient air temperature for operation-5…60 °C
[Uimp] rated impulse withstand voltage4 kV
Ratings as published by Schneider (Schneider spec table; se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.