Siemens Betagard 5SV3 RCCB 25 A · 2 Pole · 30 mA · Type A · 5SV33126RC5SV33126RC1 / 2
BrandSiemens
CategorySwitchgear
SpecificationRCCB · 5SV3
Brand SKU5SV33126RC
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Siemens· In stock
SVisit the Siemens store

Siemens Betagard 5SV3 RCCB 25 A · 2 Pole · 30 mA · Type A · 5SV33126RC

$178.04/pc
Wholesale · 15+ units
$169.14 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$178.04 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
30 mA
$178.04 /pc
Viewing above ↑
RCCB
DP
25 A
n/a
30 mA
$30.37 /pc
RCCB
2P / 1P+N (single phase)
25 A
n/a
30 mA
$33.69 /pc
RCCB
2P / 1P+N (single phase)
25 A
n/a
30 mA
$39.57 /pc
RCCB
DP
25 A
n/a
30 mA
$41.09 /pc
RCCB
2P / 1P+N (single phase)
25 A
n/a
30 mA
$54.35 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
30 mA
$76.88 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
30 mA
$91.74 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
30 mA
$260.69 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $169.14/pc on this product, applied automatically

Siemens Betagard 5SV3 RCCB 25 A (article 5SV33126RC) is a rccb from Siemens, 5SV3 series, sold by Elume with a GST invoice and pan-India delivery. Key data: manufacturer product name RES.CUR.OP.CIRCUIT BREAKER TYPE A 25A 1+N-POLE 30MA 240V 2MW INDIA, ampere/current rating 25 A, no. of poles 2 Pole, rated voltage (v) 240V AC, tripping characteristic Type A, tripping sensitivity 30 mA. Priced at the Siemens India list price of 2026 (MRP before GST Rs 10,515), GST included in the price shown.

As published by Siemens. Verify critical parameters against the datasheet before specifying.
Siemens Siemens Betagard 5SV3 RCCB 25 A · 2 Pole · 30 mA · Type A · 5SV33126RC · 5SV33126RC
Device typeRCCB
Series5SV3
Trip curveType A
Current rating25 A
Sensitivity30 mA
Reference standardIS 12640-1 / IEC 61008
BrandSiemens
Brand SKU5SV33126RC
ELINEHRFKD2RGD
Sold asPer pc
No. Of Poles2 Pole
Rated Voltage (V)240V AC
Tripping Sensitivity30 mA
Ampere/Current Rating25 A
Tripping CharacteristicType A
Manufacturer Product NameRES.CUR.OP.CIRCUIT BREAKER TYPE A 25A 1+N-POLE 30MA 240V 2MW INDIA
Ratings as published by Siemens (eleczo.com listing; Elume). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
THIS UNIT
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is Siemens Betagard 5SV3 RCCB 25 A · 2 Pole · 30 mA · Type A · 5SV33126RC genuine and warranty-backed?

Yes. Every Siemens product on Elume is 100% genuine, sourced through authorised channels, and carries the manufacturer's standard warranty.

Do you deliver outside India?

Yes, to every country except Pakistan, North Korea, Iran, Syria, Cuba, Russia, Belarus and Afghanistan, and the Crimea, Sevastopol, Donetsk, Luhansk, Zaporizhzhia and Kherson regions. The delivery fee depends on weight and destination and is shown at checkout; international orders are paid by card in US dollars. The full rules are on our shipping page.

Is there a wholesale or bulk rate?

Yes. Orders of 15 or more pcs get a wholesale price below the listed Elume price, applied automatically and shown on every product page.

No reviews yet