Schneider Schneider EasyLogic PM2220 Power Meter · 1 A · Class 1 active energy · Class 1 reactive energy · METSEPM2220D · METSEPM2220D
Rated current1 A
Ingress protectionIP54 front:· IP30 body:
Net weight0.3 kg
BrandSchneider
Brand SKUMETSEPM2220D
ELINEHH47GPKGP
Sold asPer pc
RangeEasyLogic
Control type4 x button
Display typeBacklit LCD
Product nameEasyLogic PM2200
CybersecurityEnable/disable communication ports
Metering typeApparent power S, S1, S2, S3 · Current I, I1, I2, I3 · Voltage U, U21, U32, U13, V, V1, V2, V3 · Peak demand currents · Demand power P, Q, S · Peak demand power PM, QM, SM · Unbalance current · Active, reactive, apparent energy (signed, four quadrant) · Active power P, P1, P2, P3 · Calculated neutral current · Reactive power Q, Q1, Q2, Q3
Mounting modeClip-on
Sampling rate64 samples/cycle
User languageEnglish · Portuguese · German · Chinese · Spanish · French · Russian
Accuracy classClass 1 active energy conforming to IEC 62053-21 · Class 1 reactive energy conforming to IEC 62053-24 · Class 5 harmonic distortion (I THD & U THD)
Data recordingMin/max for 8 parameters · Time stamping
Display colourMonochrome
input impedanceCurrent (impedance 5 MOhm)
Demand intervalsConfigurable from 1 to 60 min
Local signallingRed LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) · Green LED: module operation and integrated communication
Mounting supportFramework
Number of inputs0
Device short namePM2220
Mounting positionVertical
Network frequency50 Hz · 60 Hz
Number of outputs0
Ride-through time100 ms 120 V AC typical · 400 ms 230 V AC typical · 50 ms 125 V DC typical
Device applicationPower monitoring · Sub billing
Display resolution128 x 128 pixels
Function availableReal time clock
Provided equipment1 x installation guide
[In] rated current1 A · 5 A
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50/60 Hz between phases · 20…277 V AC 50/60 Hz between phase and neutral · 480…999000 V AC 50/60 Hz with external VT
Type of measurementApparent power min/max, total · Active and reactive power min/max, total · Current min/max, avg · Voltage min/max, avg · Frequency min/max, avg · Total current harmonic distortion THD (I) per phase · Total voltage harmonic distortion THD (U) per phase · Power factor min/max, avg · Apparent energy total · Active and reactive energy total
Measurement accuracyApparent power +/- 1 % · Active energy +/- 1 % · Reactive energy +/- 1 % · Active power +/- 1 % · Voltage +/- 0.5 % · Power factor +/- 0.01 · Current +/- 0.5 % · Frequency +/- 0.05 %
Measurement categoryCategory III 480 V · Category II 480…600 V
Communication serviceRemote monitoring
Information displayedDemand current (past value) · Demand current (present value) · Demand power (past value) · Demand power (present value) · Voltage · Current · Frequency · Energy consumption · Harmonic distortion · Power factor · Active power · Apparent power · Reactive power · Unbalanced in % · Harmonic amplitude
Power quality analysistotal harmonic distortion · up to the 15th harmonic
Product certificationsCE conforming to IEC 61010-1 · CULus conforming to UL 61010-1 · CULus conforming to CSA C22.2 No 61010-1 · RCM · EAC · C-Tick
Tamperproof of settingsProtected by access code
Product or component typePower meter
[Us] rated supply voltage44...277 V AC 45...65 Hz +/- 10 % · 44...277 V DC +/- 10 %
Communication port supportScrew terminal block: RS485
Communication port protocolModbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Electrical insulation classClass II · Double insulation
Frequency measurement range45…65 Hz
Maximum power consumption in W3.3 W (power lines (AC)) · 2 W at 277 V (power lines (DC))
Maximum power consumption in VA6 VA at 277 V AC
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.