Schneider Schneider EcoStruxure PAS600 Gateway · EcoStruxure Panel Server · universal wireless · PAS600
Ingress protectionIP40 (front face)
Reference standardIEC 61010
Net weight0.201 kg
BrandSchneider
Brand SKUPAS600
ELINEGP4G42HK6
Sold asPer pc
Depth70.2 mm
RangeEcoStruxure
Width72 mm
Height93 mm
TopologySeparated Ethernet network · Switched Ethernet network
StandardsIEC 61010 · IEC 61010-1 · IEC 61010-2-201 · UL 61010 · UL 61010-1 · UL 61010-2-201 · EN 61010-1 · EN 61010-2-201 · CAN/CSA C22.2 No. 61010-1-12 · CAN/CSA C22.2 No. 61010-2-201 · IEC 62974-1 · IEC 61326-1 · EN 61326-1 · ETSI EN 301 489-1 · ETSI EN 301 489-17 · EN 301-893 · EN 55032 · CISPR 11 · ETSI EN 300 328 · IEEE 802.15.4 · IEEE 802.11a/b/g/n · IEEE 802.3 af/at · FCC CFR 47 part 15 class A · EN
Product namePanel Server Universal
Web servicesHTTPS server · SFTP publication (CSV / JSON) · HTTPS publication (CSV / JSON)
Mounting modeClip-on
Connector typeHW V2: connector(s)1 x RP-SMA Wi-Fi for antenna bottom · HW V2: connector(s)1 x RP-SMA IEEE 802.15.4 for antenna top · HW V1: connector(s)1 x RP-SMA Wi-Fi for antenna bottom
Data recordingReal time data monitoring
Realtime clockWith RTC-battery set · With user calibration
Memory capacityHW V2: 32 GB eMMC · HW V1: 512 MB NAND
Mounting supportDIN rail
Number of inputs0
Device short namePAS600
Number of devices64 Modbus TCP/IP
Relative humidity5…95 %
Tightening torquePower supply: 0.6 N.m · Communication: 0.25 N.m
Device applicationGateway
Function availableEmbedded web page for configuration and upgrade · Diagnosis capabilities · Diagnostic report · Diagnostics on communication · Energy management · With integrated web server · Firmware update · Backup/restore configuration · Configurable event
Range compatibilityEcoStruxure Facility Expert · EcoStruxure Building Operation · EcoStruxure Power Operation · EcoStruxure Power Monitoring Expert · EcoStruxure Asset Advisor · EcoStruxure Energy Hub · EcoStruxure Resource Advisor · Third party SCADA
Number of connectorsHW V2: 2 screw connector for Wi-Fi and IEEE 802.15.4 · HW V1: 1 screw connector for Wi-Fi
Communication gatewayEthernet TCP/IP to wireless devices · Ethernet/serial
Communication serviceDevice Profile for Web Services (DPWS) · Modbus TCP client · Modbus TCP server · SNTP client · DHCP client · RSTP
Product compatibilityWireless access point
Wire stripping lengthPower supply: 7 mm · Communication: 7 mm
Product certificationsCE · cULus · CB · RCM · UKCA · FCC · IC · DNV Marine · ANSI RF · IACS E10
Commissioning interfaceEcoStruxure Power Commission desktop · EcoStruxure Power Commission Mobile (through Wi-Fi Access point) · EcoStruxure Power Commission web (for third party device integration) · Web page
Connections - terminalsPower supply: screw terminal block (top) 1.5…2.5 mm² cable(s) · Communication: screw terminal block (bottom) 0.14…1.5 mm² cable(s)
IP degree of protectionIP40 (front face) · IP20 (casing)
Communication iinterfaceModbus and wireless (IEEE802.15.4) product
Product or component typeGateway
[Us] rated supply voltage110...277 V AC 50/60 Hz · 110...277 V DC
Communication network typeHW V2: Wi-Fi infrastructure5 GHz · HW V2: Wi-Fi infrastructure2.4 GHz · HW V1: Wi-Fi infrastructure 10/100BASE-T2.4 GHz · Ethernet 10/100BASE-T2.4 GHz · Wi-Fi access point IEEE 802.15.42.4 GHz · Wireless IEEE 802.15.4 even/odd or none parity 1.2...115.2 kbit/s · Modbus RTU Modbus RTU client even/odd or none parity 1.2...115.2 kbit/s
Communication port support2 RJ45: ETHERNET · Screw terminal block: RS485
Number of server device(s)32 Modbus RTU product(s) · 128 Modbus TCP/IP product(s) · 40 wireless (IEEE 802.15.4) product(s) - mixed · 85 wireless (IEEE 802.15.4) product(s) - depending on configuration
Communication port protocolModbus TCP · DHCP · HTTPS · NTP/SNTP · IPv4 · IPv6 · TCP/IP
Product specific applicationWireless Schneider Electric devices ecosystem
Time synchronisation protocolNTP · SNTP
Maximum power consumption in WHW V2: 3.5 W 110...277 V · HW V1: 3 W 110...277 V
Maximum power consumption in VAHW V2: 12 VA at 110...277 V · HW V1: 10 VA at 110...277 V
Ambient air temperature for operation-25…70 °C
Data buffer for data publication (cloud, SFTP, HTTPS) depending on network1 month(s)
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.