Legrand DX³ RCBO Compact · 4P (FP) · 25 A · 30 mA · A Type · 415 V · 411431411431↓ 26% off1 / 3
BrandLegrand
CategorySwitchgear
SpecificationFour Pole · 25 A · 30 mA · A Type · 415 V
Brand SKU411431
AvailabilityOn order · 2 to 3 weeks
Delivery8 to 15 business days after dispatch
Legrand· On order, 2 to 3 weeks
Visit the Legrand store

Legrand DX³ RCBO Compact · 4P (FP) · 25 A · 30 mA · A Type · 415 V · 411431

$137.24/pc-26%
$185.45
Wholesale · 15+ units
$130.37 /pc
Add to cart
Buy now
On order: delivered in 2 to 3 weeks. We order it from Legrand for you once you place the order.
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$137.24 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCBO
4P / 3P+N (three phase)
25 A
-
30 mA
$137.24 /pc
Viewing above ↑
RCBO · Type AC
4P / 3P+N (three phase)
25 A
C
30 mA
$68.98 /pc
RCBO · Type AC
4P / 3P+N (three phase)
25 A
C
30 mA
$86.77 /pc
RCBO
4P / 3P+N (three phase)
25 A
-
30 mA
$99.67 /pc
RCBO · Type A
4P / 3P+N (three phase)
25 A
C
30 mA
$100.09 /pc
RCBO
4P / 3P+N (three phase)
25 A
-
30 mA
$121.69 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $130.37/pc on this product, applied automatically

Legrand DX³ RCBO Compact, Four Pole, 25 A, 30 mA, A Type, 415 V. Legrand catalogue number 411431.

As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DX³ RCBO Compact · 4P (FP) · 25 A · 30 mA · A Type · 415 V · 411431 · 411431
SeriesDX³
Poles4P (FP)
Rated current25 A
Sensitivity (IΔn)30 mA
Device typeMiniature circuit breaker (MCB)
Current rating25 A
Reference standardIS/IEC 60898-1
BrandLegrand
Brand SKU411431
ELINEF9HHK2HFM
Sold asPer pc
Ratings as published by Legrand (Product title; price list). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between RCBO and RCCB?

An RCBO combines an MCB and an RCCB in one device, protecting a single circuit against overload, short circuit and earth leakage. An RCCB only handles earth leakage and needs separate MCBs (RCBOs are covered by IS 12640 (Part 2)).

Why use RCBOs instead of one main RCCB?

With RCBOs, a leakage fault on one circuit trips only that circuit, so the rest of the house keeps power and it is easier to find the fault. They cost more and take more DB space than one RCCB with several MCBs, so many homes use RCBOs only on critical circuits like geyser, washing machine and outdoor points.

Can I use an RCBO for my geyser or water pump?

Yes, an RCBO suits geysers, pumps and other loads in wet areas because it gives shock protection and overload protection on that one circuit. Choose the current rating and curve as you would for an MCB, based on the appliance's rated current and the cable, and have a licensed electrician confirm.

Does an RCBO need a neutral connection?

Yes. The RCBO compares phase and neutral current to detect leakage, so the circuit's neutral must pass through it and must not be shared with any other circuit.

Will an RCBO fit in a normal MCB distribution board?

RCBOs mount on the standard 35mm DIN rail, but many are 2 modules wide or need a separate neutral connection, so check that your DB has enough free ways and space. Some compact single-module RCBOs fit like an SP MCB; refer to the product's module width.

No reviews yet