🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB DSB200 M RCBO · 4P (FP) · 25 A · 30 mA · Type AC · C curve · 2CSR274027R12542CSR274027R1254↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationDSB204M AC-C25/0.03 - RCCB with Over current protection
Brand SKU2CSR274027R1254
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB DSB200 M RCBO · 4P (FP) · 25 A · 30 mA · Type AC · C curve · 2CSR274027R1254

Rating: 25 A
Poles: 4
Sensitivity: 30 mA
₹4,752/pcincl. GST-53%
₹4,027 + 18% GST · MRP ₹10,070
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹4,752 /pc incl. GST
Free pan-India delivery

ABB DSB200 M RCBO · 4P (FP) · 25 A · 30 mA · Type AC · C curve · 2CSR274027R1254: Elume price today ₹4,752 per pc incl. GST, 53% below the ₹10,070 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹3,054, ₹1,698 less than here.

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹10,775₹8,768₹6,761₹4,753₹2,746₹10,070₹4,752₹3,054
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹4,752
Avg market price
₹3,054
MRP
₹10,070
Lowest in view · 27 Aug
₹2,953
Highest in view · 3 Oct
₹4,752
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCBO · Type AC
4P / 3P+N (three phase)
25 A
C
30 mA
₹4,027 +GST /pc
₹4,752 incl. GST
Viewing above ↑
RCBO · Type AC
4P / 3P+N (three phase)
25 A
C
30 mA
₹5,065 +GST /pc
₹5,977 incl. GST
RCBO
4P / 3P+N (three phase)
25 A
-
30 mA
₹5,819 +GST /pc
₹6,866 incl. GST
RCBO
4P / 3P+N (three phase)
25 A
-
30 mA
₹7,104 +GST /pc
₹8,383 incl. GST
RCBO
4P / 3P+N (three phase)
25 A
-
30 mA
₹8,012 +GST /pc
₹9,454 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹4,514/pc on this product, applied automatically

ABB DSB200 M RCBO · 30 mA · 25 A · Type AC is a switchgear device from ABB. Key ratings: Poles 4P (FP), Rated current 25 A, Sensitivity 30 mA, Type AC.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB DSB200 M RCBO · 4P (FP) · 25 A · 30 mA · Type AC · C curve · 2CSR274027R1254 · 2CSR274027R1254
Device typeResidual current breaker with overload protection (RCBO)
Poles4P (FP)
Rated current25 A
Trip curveC curve
Sensitivity (IΔn)30 mA
RCCB typeType AC
Current rating25 A
Sensitivity30 mA
Reference standardIS 12640-1 / IEC 61008
BrandABB
Brand SKU2CSR274027R1254
ELINE3G64HDPG9
Sold asPer pc
Ratings as published by ABB (shop.in.abb.com listing for 981557ff, 14 Sep 2026; Product name; Elume catalogue). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
THIS UNIT
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between RCBO and RCCB?

An RCBO combines an MCB and an RCCB in one device, protecting a single circuit against overload, short circuit and earth leakage. An RCCB only handles earth leakage and needs separate MCBs (RCBOs are covered by IS 12640 (Part 2)).

Why use RCBOs instead of one main RCCB?

With RCBOs, a leakage fault on one circuit trips only that circuit, so the rest of the house keeps power and it is easier to find the fault. They cost more and take more DB space than one RCCB with several MCBs, so many homes use RCBOs only on critical circuits like geyser, washing machine and outdoor points.

What is the sensitivity of this RCBO?

This RCBO trips on leakage at 30 mA, in addition to normal overload and short-circuit protection. 30mA is the usual choice for shock protection on final circuits.

Can I use an RCBO for my geyser or water pump?

Yes, an RCBO suits geysers, pumps and other loads in wet areas because it gives shock protection and overload protection on that one circuit. Choose the current rating and curve as you would for an MCB, based on the appliance's rated current and the cable, and have a licensed electrician confirm.

Does an RCBO need a neutral connection?

Yes. The RCBO compares phase and neutral current to detect leakage, so the circuit's neutral must pass through it and must not be shared with any other circuit.

Will an RCBO fit in a normal MCB distribution board?

RCBOs mount on the standard 35mm DIN rail, but many are 2 modules wide or need a separate neutral connection, so check that your DB has enough free ways and space. Some compact single-module RCBOs fit like an SP MCB; refer to the product's module width.

No reviews yet