🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Legrand DX3 RCCB · 2P (DP) · 25 A · 300 mA · 411861411861↓ 26% off1 / 3
BrandLegrand
CategorySwitchgear
Specification2P (DP) · 25 A · 300 mA
Brand SKU411861
AvailabilityReady to ship · Only 6 left · Ships tomorrow
Delivery8 to 15 business days after dispatch
Legrand· Ready to ship
Visit the Legrand store

Legrand DX3 RCCB · 2P (DP) · 25 A · 300 mA · 411861

$65.92/pc-26%
$89.09
Wholesale · 15+ units
$62.63 /pc
Add to cart
Buy now
Ready to shipOnly 6 left
Ships tomorrow.
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$65.92 /pc
Delivery in 8 to 15 business days
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB
2P / 1P+N (single phase)
25 A
n/a
300 mA
$65.92 /pc
Viewing above ↑
RCCB · Type AC
2P / 1P+N (single phase)
25 A
n/a
300 mA
$30.85 /pc
RCCB
2P / 1P+N (single phase)
25 A
n/a
300 mA
$43.21 /pc
RCCB · Type AC
2P / 1P+N (single phase)
25 A
n/a
300 mA
$46.33 /pc
RCCB · Type AC
2P / 1P+N (single phase)
25 A
n/a
300 mA
$63.83 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
300 mA
$81.38 /pc
RCCB · Type AC
2P / 1P+N (single phase)
25 A
n/a
300 mA
$81.86 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
300 mA
$113.62 /pc
RCCB · Type A
2P / 1P+N (single phase)
25 A
n/a
300 mA
$127.40 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $62.63/pc on this product, applied automatically

Legrand DX3 RCCB, 2P (DP), 25 A, 300 mA. Legrand catalogue number 411861.

As published by Legrand. Verify critical parameters against the datasheet before specifying.
Legrand Legrand DX3 RCCB · 2P (DP) · 25 A · 300 mA · 411861 · 411861
SeriesDX3
Poles2P (DP)
Rated current25 A
Sensitivity (IΔn)300 mA
Device typeResidual current circuit breaker (RCCB)
Current rating25 A
Sensitivity300 mA
Reference standardIS 12640-1 / IEC 61008
BrandLegrand
Brand SKU411861
ELINED7DDFGPMH
Sold asPer pc
Ratings as published by Legrand (Product title; stock description). Verify critical parameters against the datasheet before specifying.
Other Legrand ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.

No reviews yet