Schneider Schneider PowerLogic PM3210 Power Meter · 1P/3P · 1 A · Class 0.5S active energy · METSEPM3210 · METSEPM3210
Rated current1 A
Ingress protectionIP40 front panel:· IP20 body:
Reference standardBS EN 61557-12
Net weight0.26 kg
BrandSchneider
Brand SKUMETSEPM3210
ELINED4RC227R9
Sold asPer pc
Depth70 mm
RangePowerLogic
Width90 mm
Height95 mm
StandardsBS EN 61557-12 · IEC 61557-12 · EN 61557-12 · BS EN 61326-1 · IEC 61326-1 · EN 61326-1 · BS EN 62052-11 · IEC 62052-11 · EN 62052-11 · BS EN 62053-21 · IEC 62053-21 · EN 62053-21 · BS EN 62053-22 · IEC 62053-22 · EN 62052-22 · BS EN 62053-23 · IEC 62053-23 · EN 62052-23 · BS EN 61010-1 · EN 61010-1 · IEC 61010-1 · UL 61010-1 · BS EN 61010-2-30 · IEC 61010-2-30 · EN 61010-2-30 · UL 61010-2-30 · ANS
Display typeBacklit LCD
Product namePowerLogic PM3000
Mounting modeClip-on
Sampling rate32 samples/cycle
Accuracy classClass 0.5S active energy conforming to IEC 62053-22 · Class 1 active energy conforming to IEC 62053-21 · Class 2 reactive energy conforming to IEC 62053-23 · Class C active energy conforming to EN 50470-3
Data recordingTime stamping · 5 alarms · Min/max of instantaneous values
Market segmentBuildings small building cost management: billing: sub feeder · Buildings medium building cost management: billing: sub feeder · Buildings large building cost management: billing: sub feeder · Buildings multi-site cost management: billing: sub feeder · Data center cost management: billing: sub feeder · Healthcare cost management: billing: sub feeder · Industry cost management: billing: sub feeder
supply voltage100...277 V AC 45...65 Hz · 173...480 V AC 45...65 Hz · 100...300 V DC
type of network3P · 3P + N · 1P + N
Mounting supportDIN rail
Number of inputs0
Pollution degree2
Device short namePM3210
Network frequency50 Hz · 60 Hz
Number of outputs1 pulse
Relative humidity5…95 % at 50 °C
Compatibility codePM3210
Device applicationPower monitoring · Multi-tariff · Sub billing
Display resolution128 x 96 pixels
Operating altitude< 3000 m
[In] rated current1 A · 5 A
Analogue input typeCurrent 0...5 A · Current 0...1 A
Measurement current0.05…6 A · 0.02…1.2 A
Measurement voltage50…330 V AC 45...65 Hz direct · 50…330 V AC 45...65 Hz phase to neutral · 80…570 V AC 45...65 Hz direct · 80…570 V AC 45...65 Hz phase to phase · 570…999000 V AC 45...65 Hz with external VT
Type of measurementActive and reactive power · Apparent power · Current · Voltage · Energy · Power factor · Frequency · Total current harmonic distortion THD (I) · Total voltage harmonic distortion THD (U)
Measurement accuracyCurrent 0.3 % 0.5...6 A · Current 0.5 % 0.1...1.2 A · Voltage 0.3 % 50...330 V · Voltage 0.3 % 80...570 V
Overvoltage categoryIII
Information displayedTariff (4)
Power quality analysisup to the 15th harmonic
Product certificationsCE conforming to IEC 61010-1 (safety) · CE conforming to EN 61557-12 (power monitor) · CE conforming to EN/IEC 61326-1 (EMC) · UKCA conforming to BS EN 61010-1 (safety) · UKCA conforming to BS EN 61557-12 (power monitor) · UKCA conforming to BS EN 61326-1 (EMC) · CULus conforming to EN 61010-1 (safety) · CULus conforming to UL 61010-1 (safety) · EAC (sub-meter) · RCM
IP degree of protectionIP40 front panel: conforming to IEC 60529 · IP20 body: conforming to IEC 60529
Power consumption in VA5 VA
Product or component typePower meter
Communication port support-
Communication port protocol-
Frequency measurement range45…65 Hz
Electromagnetic compatibilityElectrostatic discharge level 4 conforming to IEC 61000-4-2 · Susceptibility to electromagnetic fields level 3 conforming to IEC 61000-4-3 · Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 · Surge immunity test level 4 conforming to IEC 61000-4-5 · Conducted RF disturbances level 3 conforming to IEC 61000-4-6 · Magnetic field at power frequency - test level: 0.5 m
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…70 °C