Schneider EasyLogic PM1220H Energy Meter · 1P/3P · 1 A · Class 1 active energy · Class 1 re · IP51 · METSEEM1220HCL1METSEEM1220HCL1↓ 40% off
BrandSchneider
CategoryIndustrial Control
Specification1P/3P · 1 A · Class 1 active energy· Class 1 re · Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Brand SKUMETSEEM1220HCL1
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider EasyLogic PM1220H Energy Meter · 1P/3P · 1 A · Class 1 active energy · Class 1 re · IP51 · METSEEM1220HCL1

$143.52/pc-40%
$239.23
Wholesale · 15+ units
$136.36 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$143.52 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $136.36/pc on this product, applied automatically

This panel mount meter is part of the EasyLogic PM1000H series. Providing Class 1 active energy accuracy per IEC 62053-21 standard, the meter will measure voltage, current and power factor. Measurement of RPM, Voltage, current or frequency per phase. Communication protocol is Modbus with RS485 port support. The meter has a 4 digits, eight segments, 15 mm height and bright red LED display. Mechanical dimensions are 96 mm in width, 96 mm in height and 80 mm in depth, for a product weight of 300 g.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider EasyLogic PM1220H Energy Meter · 1P/3P · 1 A · Class 1 active energy · Class 1 re · IP51 · METSEEM1220HCL1 · METSEEM1220HCL1
Rated current1 A
Ingress protectionIP51 front:· IP30 body:
Reference standardIEC 61010-1:ed. 3
Net weight0.3 kg
BrandSchneider
Brand SKUMETSEEM1220HCL1
ELINECC27PHMCP
Sold asPer pc
ModelPM1220H
RangeEasyLogic
Width96 mm
SignalVoltage (impedance 5 MOhm)4 x · Current 0.005...10 A (impedance 0.3 MOhm)6 x
MaterialPolycarbonate
StandardsIEC 61010-1:ed. 3 · UL 61010-1:ed. 3
Display typeLCD display
Metering typeAverage current Iavg · Phase currents · Active power P, P1, P2, P3 · Active, reactive, apparent energy (signed, four quadrant) · Rotation speed · Average voltage Vavg · Calculated neutral current · Unbalance current · Unbalance voltage · Frequency · Voltage U21, U32, U13, V1, V2, V3 · Demand power P, Q, S · Power factor and displacement PF (signed, four quadrant) · Phase current I1, I2, I3 RMS
Mounting modeFlush-mounted
Sampling rate32 samples/cycle
Accuracy classClass 1 active energy conforming to IEC 62053-21 · Class 1 reactive energy conforming to IEC 62053-24
Data recordingEnergy consumption logs
Display colourMonochrome
Display digits12 digit(s)
type of network3P · 2P + N · 1P + N · 3P + N · 2P
Demand intervals1 s
Flame retardanceV-0 conforming to UL 94
Local signallingGreen LED: activity · Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) · LED: voltage indication
Mounting supportFramework
Counter functionsON hour counting · ON-load hour counting · Power interruption
Network frequency50 Hz · 60 Hz
Tightening torqueCurrent circuit: 0.9…1 N.m Philips No 2 screwdriver · Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver · Control circuit: 0.9…1 N.m Philips No 2 screwdriver · Communication: 0.5…0.6 N.m Philips no 1 screwdriver
Device applicationEnergy monitoring
Provided equipmentInstallation guide
[In] rated current1 A · 5 A
Measurement current5…6000 mA
Measurement voltage46…277 V AC 50...60 Hz between phase and neutral · 80…480 V AC 50...60 Hz between phases · 277…999000 V AC 50...60 Hz with external VT
Type of measurementCurrent · Voltage · Frequency · Power factor · Phase angle · RPM · Peak demand power · Harmonic distortion (I THD & U THD) · Active power · Active energy
Measurement accuracyCurrent +/- 0.5 % · Voltage +/- 0.5 % · Frequency +/- 0.05 % · Power factor +/- 0.01 · Reactive power +/- 2 % · Active power +/- 1 % · Apparent power +/- 1 % · Active energy +/- 1 % · Reactive energy +/- 2 % · Apparent energy +/- 1 % · Harmonic distortion (I THD & U THD) +/- 5 %
Measurement categoryCategory III 480 V
Type of installationIndoor installation
Communication of dataReading of measurements · All counters · Revolution speed · Last cleared log · Instantaneous and demand values
Installation categoryIII
Wire stripping lengthCurrent circuit: 3.68 mm · Voltage circuit: 7 mm · Control circuit: 7 mm · 7 mm
Power quality analysistotal harmonic distortion
Product certificationsCE conforming to IEC 61010-1 · CULus conforming to UL 61010-1 · CULus conforming to CSA C22.2 No 61010-1 · C-Tick
Connections - terminalsCurrent circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) · Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) · Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) · Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s)
Tamperproof of settingsProtected by access code
Product or component typeEnergy meter
[Us] rated supply voltage48...277 V AC/DC
Communication port supportScrew connector: RS485
Communication port protocolModbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Electrical insulation classClass II
Frequency measurement range45…65 Hz
Maximum power consumption in W2 W at 240 V
Maximum power consumption in VA4 VA at 240 V
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
No reviews yet