🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Out of stock · in stock hereOrient · Eurotech Isolator Four Pole · 100 A$24.31$30.98
Orient Eurotech Isolator Triple Pole · 100 A161TP0100↓ 22% off
BrandOrient
CategorySwitchgear
Specification100 A · 3P
Brand SKU161TP0100
AvailabilityOut of stock
Delivery8 to 15 business days after dispatch
Orient· Out of stock
Visit the Orient store

Orient Eurotech Isolator Triple Pole · 100 A

Rating: 100A
struck through = out of stock
$20.87/pc-22%
$26.61
Out of stock
This one cannot be ordered right now. These match its specification and are in stock:
Same specificationISOLATOR · TP · 100 A
OrientSame product
Eurotech Isolator Four Pole · 100 A
$24.31/pc-22%
$30.98
Lauritz KnudsenIn stock
Exora Isolator · 3P (TP) · 100 A · 415 V AC · BF310000
$20.52/pc-37%
$32.55
LegrandIn stock
DX3 Isolator · 3P (TP) · 100 A · 406513
$21.65/pc-33%
$32.20
Compare all 6 in-stock alternatives ↓
Need this exact model? Email info@elumenuvo.com and we will source it for you.
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
ISOLATOR
TP
100 A
n/a
-
$20.87 /pc
Viewing above ↑
ISOLATOR
TP
100 A
n/a
-
$20.52 /pc
ISOLATOR
TP
100 A
n/a
-
$21.65 /pc
ISOLATOR
TP
100 A
n/a
25 kA
$28.28 /pc
ISOLATOR
TP
100 A
n/a
-
$35.51 /pc
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $19.83/pc on this product, applied automatically

Orient Eurotech Isolator Triple Pole is a switchgear product from Orient. Key ratings: rated current 100 A, poles 3P.

As published by Orient. Verify critical parameters against the datasheet before specifying.
Orient Orient Eurotech Isolator Triple Pole · 100 A · 161TP0100
Poles3P (TP)
Rated current100 A
Device typeSwitch disconnector (isolator)
Current rating100 A
Reference standardIEC 60947-3
BrandOrient
Brand SKU161TP0100
ELINEC4M4H77G3
Sold asPer pc
Ratings as published by Orient (orientelectric.com). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between an isolator and an MCB?

An isolator (switch-disconnector) only switches the circuit on and off and does not trip on overload or short circuit, while an MCB provides protection. Isolators are used as main switches in DBs or near equipment for safe maintenance, and must be backed by a suitable MCB, MCCB or fuse.

Can I use an isolator as the main switch in my DB?

Yes, a DP isolator for single-phase or 4P isolator for three-phase is commonly used as the DB incomer, provided protection is given upstream (by the meter-side fuse or MCB) and on each outgoing circuit. Its current rating should be equal to or higher than the upstream protection rating.

Is this isolator safe to switch on load?

Switch-disconnectors to IS/IEC 60947-3 are rated for switching under load according to their utilisation category, such as AC-22 for mixed resistive and inductive loads or AC-23 for motor loads. Check the category on the product before using it to switch motors directly.

What current rating does this isolator have?

It is rated 100A. Choose a rating at least equal to the upstream MCB or fuse so the isolator is never the weakest link in the circuit.

2 pole or 4 pole isolator - which one do I need?

Use 2 pole for single-phase supply (phase and neutral) and 4 pole for three-phase supply with neutral, so all live conductors are disconnected during maintenance. A 3 pole isolator is used where no neutral is switched, such as some motor feeders.

Can an isolator be locked off for maintenance?

Many isolators and rotary switch-disconnectors have a padlocking provision in the OFF position so no one can switch them on while work is in progress. Check for the lock-off feature if it is needed for your site's safety procedures.

No reviews yet