Schneider Schneider Acti9 iEM3350 Energy Meter · 125 A · Class 1 active energy · Class 1 · A9MEM3350 · A9MEM3350
Poles3P+N (TPN)
Rated current125 A
Ingress protectionIP40 front panel:· IP20 body:
Reference standardBS EN 61557-12:2021
ColourWhite
BrandSchneider
Brand SKUA9MEM3350
ELINE4D6M94RKH
Sold asPer pc
Depth69.3 mm
RangeActi9
Width126 mm
Height103.2 mm
StandardsBS EN 61557-12:2021 · IEC 61557-12:2021 · EN 61557-12:2021 · BS EN 61326-1 · IEC 61326-1 · EN 61326-1 · BS EN 62052-11:2020 · IEC 62052-11:2020 · EN 62052-11:2020 · BS EN 62053-21 · IEC 62053-21 · EN 62053-21 · BS EN 62052-31:2015 · IEC 62052-31:2015 · EN 62052-31:2015 · BS EN 61010-1:2010 · EN 61010-1:2010 · IEC 61010-1:2010 · UL 61010-1:2010 · BS EN 61010-2-30 · IEC 61010-2-30 · EN 61010-2-30 ·
input typeDirect connection
9 mm pitches14
Display typeLCD display
Mounting modeClip-on
Rated voltage100…277 V · 173…480 V
Sampling rate32 samples/cycle
Accuracy classClass 1 active energy conforming to IEC 62053-21 · Class 1 active energy conforming to IEC 61557-12
Market segmentBuildings small building cost management: billing: main incomer · Buildings small building cost management: billing: sub feeder · Buildings small building cost management: billing: panelboard · Buildings medium building cost management: billing: main incomer · Buildings medium building cost management: billing: sub feeder · Buildings medium building cost management: billing: panelboard · Buildings
Technology typeElectronic
Local signallingGreen indicator light: power ON · Yellow flashing LED: accuracy checking · Yellow indicator light: communications are active on the Modbus port (Modbus)
Mounting supportDIN rail
Number of inputs0
Pollution degree2
range of productActi9 iEM3000
Device short nameiEM3350
Network frequency50 Hz · 60 Hz
Number of outputs0
Poles description3P + N · 3P · 1P + N
Relative humidity5…95 % at 50 °C
Compatibility codeIEM3350
Device applicationPartial meter · Sub billing
Operating altitude< 3000 m
[In] rated current125 A
Measurement current0…125 A
Type of measurementActive energy · Current · Voltage · Active power
Overvoltage categoryIII
Maximum value measured99999999.9 kWh
Product certificationsCE conforming to IEC 61010-1 (safety) · CE conforming to EN 61557-12 (power monitor) · CE conforming to EN/IEC 61326-1 (EMC) · UKCA conforming to BS EN 61010-1 (safety) · UKCA conforming to BS EN 61557-12 (power monitor) · UKCA conforming to BS EN 61326-1 (EMC) · CULus conforming to UL 61010-1 (safety) · CULus conforming to EN 61010-1 (safety) · EAC (sub-meter) · KZ conforming to NMI M 6-1 · KZ ·
Connections - terminalsScrew terminals 50 mm² cable(s)
IP degree of protectionIP40 front panel: conforming to IEC 60529 · IP20 body: conforming to IEC 60529
Product or component typeEnergy meter
Communication port supportScrew terminal block: RS485
Communication port protocolModbus RTU at 9.6, 19.2 and 38.4 kbauds even/odd or none, insulation 4000 V
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-25…70 °C - IEC
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.