🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
Schneider EasyLogic Energy Meter · 1P/3P · 5 A · Class 2 reactive energy · Class 0.5 · METSEPM1230HCL5METSEPM1230HCL5↓ 40% off
BrandSchneider
CategoryIndustrial Control
Specification1P/3P · 5 A · Class 2 reactive energy· Class 0.5 · Modbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Brand SKUMETSEPM1230HCL5
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider EasyLogic Energy Meter · 1P/3P · 5 A · Class 2 reactive energy · Class 0.5 · METSEPM1230HCL5

$223.42/pc-40%
$372.36
Wholesale · 15+ units
$212.25 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$223.42 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $212.25/pc on this product, applied automatically

The EasyLogic PM1000H series basic power and energy meters offer all the measurement capabilities required to monitor an installation. Measured parameters are power, energy (delivered and received), harmonic distortion and selectable demand energy. The navigation is assured by 4 panel buttons. Configuration and clearing are protected by an user configured password (4 digits). Providing Class 0.5S active energy accuracy per IEC 62053-21 standard, the meter will measure active and reactive energy. Communication protocol is Modbus RTU with RS485 port support. The LCD screen, with a resolution of 128x32 pixels, is used to display the multiple parameter measurement. Mechanical dimensions are 96 mm in width, 96 mm in height and 63 mm in depth, for a product weight of 300 g.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider EasyLogic Energy Meter · 1P/3P · 5 A · Class 2 reactive energy · Class 0.5 · METSEPM1230HCL5 · METSEPM1230HCL5
Rated current5 A
Ingress protectionIP51 front:· IP30 body:
Reference standardIEC 61010-1:ed. 3
Net weight0.3 kg
BrandSchneider
Brand SKUMETSEPM1230HCL5
ELINE494KDMK66
Sold asPer pc
RangeEasyLogic
SignalVoltage (impedance 5 MOhm)4 x · Current 0.005...10 A (impedance 0.3 MOhm)6 x
MaterialPolycarbonate
StandardsIEC 61010-1:ed. 3 · UL 61010-1:ed. 3
Display typeBacklit LCD
Metering typeCalculated neutral current · Rotation speed · Phase currents · Active power P, P1, P2, P3 · Unbalance current · Power factor and displacement PF (signed, four quadrant) · Active, reactive, apparent energy (signed, two quadrant) · Reactive power Q, Q1, Q2, Q3 · Apparent power S, S1, S2, S3 · Demand power P, Q, S · Frequency · Voltage U21, U32, U13, V1, V2, V3 · Unbalance voltage · Phase current I1,
Mounting modeFlush-mounted
Sampling rate32 samples/cycle
Accuracy classClass 2 reactive energy conforming to IEC 62053-23 · Class 0.5 active energy conforming to IEC 62053-22
Data recordingEnergy consumption logs
Display colourMonochrome
Output voltage300 V AC@2 A
type of network3P + N · 3P · 2P · 1P + N · 2P + N
Demand intervals1 s
Flame retardanceV-0 conforming to UL 94
Local signallingGreen LED: activity · Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) · Red LED: alternate source · LED: voltage indication
Mounting supportFramework
Counter functionsPower interruption · ON-load source 1 hour counting · ON-load source 2 hour counting · ON hour counting
Network frequency60 Hz · 50 Hz
Number of outputs1 relay
Tightening torqueCurrent circuit: 0.9…1 N.m Philips No 2 screwdriver · Voltage circuit: 0.9…1 N.m Philips No 2 screwdriver · Control circuit: 0.9…1 N.m Philips No 2 screwdriver · Communication: 0.5…0.6 N.m Philips no 1 screwdriver · Secondary circuit: 0.5…0.6 N.m Philips no 1 screwdriver · Relay output: 0.5…0.6 N.m Philips no 1 screwdriver
Device applicationMain or redundant power monitoring · Energy monitoring
Display resolution122 x 32 pixels
Provided equipmentInstallation guide
[In] rated current5 A · 1 A
Measurement current5…6000 mA
Measurement voltage35…480 V AC 50...60 Hz between phases · 35…277 V AC 50...60 Hz between phase and neutral · 277…999000 V AC 50...60 Hz with external VT
Type of measurementCurrent · Voltage · Frequency · Power factor · Phase angle · RPM · Peak demand power · Harmonic distortion (I THD & U THD) · Active power · Active energy
Measurement accuracyCurrent +/- 0.5 % · Voltage +/- 0.5 % · Frequency +/- 0.05 % · Power factor +/- 0.01 · Reactive power +/- 2 % · Reactive energy +/- 2 % · Active power +/- 0.5 % · Apparent power +/- 0.5 % · Active energy +/- 0.5 % · Apparent energy +/- 0.5 % · Harmonic distortion (I THD & U THD) +/- 5 %
Measurement categoryCategory III 480 V
Type of installationIndoor installation
Communication of dataReading of measurements · All counters · Instantaneous and demand values · Last cleared log · Revolution speed
Installation categoryIII
Wire stripping lengthCurrent circuit: 3.68 mm · Voltage circuit: 7 mm · Control circuit: 7 mm · Communication: 7 mm · 7 mm
Power quality analysistotal harmonic distortion
Connections - terminalsCurrent circuit: screw clamp terminals (bottom) 2.08…3.31 mm² cable(s) · Voltage circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) · Control circuit: screw clamp terminals (top) 0.82…3.31 mm² cable(s) · Communication: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s) · Secondary circuit: screw clamp terminals (bottom) 0.33…3.31 mm² cable(s) · Relay output: screw clamp terminals (rear
Tamperproof of settingsProtected by access code
Product or component typeDual source energy meter
[Us] rated supply voltage48...277 V AC 45...65 Hz · 48...277 V DC
Communication port supportRS485
Communication port protocolModbus at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Electrical insulation classClass II
Frequency measurement range45…65 Hz
Maximum power consumption in W2 W at 240 V
Maximum power consumption in VA4 VA at 240 V between phase and neutral
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
No reviews yet