Schneider ComPacT NSX FDM121 Display Module · front display module · FDM 121 · 96 x 96 mm · IP54 · TRV00121TRV00121↓ 40% off1 / 3
BrandSchneider
CategorySwitchgear
Specificationfront display module · FDM 121 · 96 x 96 mm · IP54
Brand SKUTRV00121
AvailabilityIn stock · ships in 24h
Delivery8 to 15 business days after dispatch
Schneider· In stock
Visit the Schneider store

Schneider ComPacT NSX FDM121 Display Module · front display module · FDM 121 · 96 x 96 mm · IP54 · TRV00121

$269.60/pc-40%
$449.31
Wholesale · 15+ units
$256.11 /pc
Add to cart
Buy now
Delivery in 8 to 15 business days after dispatch
Buying in bulk? Ask our Export desk for a quote.
$269.60 /pc
Delivery in 8 to 15 business days
🏷️
100% genuine
Brand-authorised stock, sourced through authorised channels
🧾
Export invoice
Every international order ships with an export invoice for customs
🌍
Worldwide delivery
Dispatched from Ghaziabad, India · fee by weight, shown at checkout
📦
Wholesale built in
Wholesale price at 15+ units: $256.11/pc on this product, applied automatically

This FDM121 is an Ethernet switchboard display module and it is part of EnerlinX communication system. This display unit is compatible with Masterpact, Compact and PowerPact circuit breakers. FDM121 displays the measurements, alarms, and operating assistance data from one circuit breaker over ULP. Its LCD screen offers a high resolution with white backlighting. The FDM121 is equipped with a 24VDC terminal block and two RJ45 sockets for ULP connection. It is easily installed in a switchboard, either through a standard door cut-out (92x92mm) or two 22mm diameter holes. It is a 96 x 96 x 30 mm screen requiring 10 mm behind the door (or 20 mm when the 24 V power supply connector is used) The operating temperature range is between -10°C to 55°C, and the protection degree is IP54 on the front face. The FDM121 display module is entirely part of the EcoStruxure Power architecture and Ethernet ready smart panels. The FDM121 firmware can be updated using EcoStruxure Power Commission software.

As published by Schneider. Verify critical parameters against the datasheet before specifying.
Schneider Schneider ComPacT NSX FDM121 Display Module · front display module · FDM 121 · 96 x 96 mm · IP54 · TRV00121 · TRV00121
Ingress protectionIP53 front face:
Reference standardCE
Device typeMiniature circuit breaker (MCB)
BrandSchneider
Brand SKUTRV00121
ELINE26CMFCFR3
Sold asPer pc
Depth33.6 mm
Width96 mm
Height96 mm
StandardsCE · CSA · UL
Control typeRemote control
Display typeLCD screen with white backlighting
Product nameEnerlin'X FDM
Mounting modeFlush mounting
Mounting supportSurface mount with kit · Door cut-out
Device short nameFDM121
Display resolution128 x 128 pixels
Function of moduleRemote control · View network · Metering · Display alarm
Current consumption21 mA
Range compatibilityMasterPact MTZ · MasterPact NW · MasterPact NT · Compact NSX · ComPact ComPact NS630b...1600 · ComPact ComPact NS1600b...3200 · PowerPact PowerPact H · PowerPact PowerPact J · PowerPact PowerPact L · PowerPact PowerPact P · PowerPact PowerPact R
IP degree of protectionIP53 front face:
Product or component typeDisplay module
[Us] rated supply voltage24 V DC - 20...10 %
View angle horizontal x vertical60 x 30°
Accessory / separate part categoryDisplay and signalling accessory
Ambient air temperature for storage-40…85 °C
Ambient air temperature for operation-10…55 °C
Ratings as published by Schneider (se.com). Verify critical parameters against the datasheet before specifying.
Other Schneider ranges and models in this category, closest in price to this one.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
When do I need an MCCB instead of an MCB?

MCBs typically go up to 63A or 125A, so MCCBs are used for higher currents (roughly 16A to 1600A), as main incomers of buildings, panels and sub-panels, or where higher breaking capacity and adjustable settings are needed. MCCBs are covered by IS/IEC 60947-2.

What is the difference between Icu and Ics?

Icu is the ultimate breaking capacity the MCCB can interrupt once, while Ics is the service breaking capacity it can interrupt and still remain usable. Choose an MCCB whose Icu exceeds the prospective fault current at the installation point; for critical feeders, a higher Ics (ideally 100% of Icu) is preferred.

Should I take a 3 pole or 4 pole MCCB?

Use 3 pole where only the phases need switching, and 4 pole where the neutral must also be isolated, such as generator changeover systems, incomers with unbalanced single-phase loads or where local rules require neutral isolation. Your panel designer or electrician should decide based on the earthing system.

Can I adjust the current setting of an MCCB?

Many MCCBs have an adjustable overload setting (for example 0.8 to 1 times the frame rating, or wider on electronic releases), and some allow short-circuit adjustment too. Fixed-release MCCBs cannot be adjusted, so check the release type before buying.

What accessories can be added to an MCCB?

Common add-ons include auxiliary and trip alarm contacts, shunt trip and undervoltage releases, rotary handles for door mounting, motor operators for remote switching, and terminal spreaders or extended terminals for larger cables. Accessories are usually specific to the brand and frame size.