ABB AL16-30-01 220V DC Contactor · 1SBL183001R88011SBL183001R8801↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationAL16-30-01 220V DC · AL Contactors
Brand SKU1SBL183001R8801
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB AL16-30-01 220V DC Contactor · 1SBL183001R8801

NEW added this week
₹3,112/pcincl. GST-53%
₹2,637 + 18% GST · MRP ₹6,594
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹3,112 /pc incl. GST
Free delivery over ₹4,000

ABB AL16-30-01 220V DC Contactor · 1SBL183001R8801: Elume price today ₹3,112 per pc incl. GST, 53% below the ₹6,594 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹7,056₹6,015₹4,975₹3,935₹2,894₹6,594₹3,112
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹3,112
MRP
₹6,594
Lowest in view · 17 Nov
₹3,112
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹2,956/pc on this product, applied automatically

AL16 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The AL... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: DC operated with solid core magnet circuit. The polarity on the coil terminals (A1+ and A2-) must be respected - Accessories: a wide range of accessories is available. AL... contactors are fitted with low consumption DC coils and are suitable for a direct control by PLC outputs.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB AL16-30-01 220V DC Contactor · 1SBL183001R8801 · 1SBL183001R8801
Device typeContactor
SeriesAL Contactors
Poles3P (TP)
FrequencyAuxiliary Circuit 50 / 60 Hz
Insulation voltage (Ui)acc. to IEC 60947-4-1 1000 V
Country of originIndia
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL183001R8801
ELINE7G6K9CF93
Sold asPer pc
Operate TimeBetween Coil De-energization and NO Contact Opening 10 ... 17 millisecond
Package Width86 mm
Product ClassBlock Contactors
Terminal TypeScrew Terminals
Package Height51 mm
Package Length141 mm
Number of Poles3
Coil ConsumptionAverage Holding Value, from Warm State 3 W
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Package Gross Weight0.52 kg
Extended Product TypeAL16-30-01 220V DC
Rated Frequency Limits25 ... 400 Hz
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -25 ... 55 °C
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 5 hp
General Use Rating UL/CSA(600 V AC) 30 A
Number of Aux Contacts NC1
Number of Aux Contacts NO0
Number of Main Contacts NC0
Number of Main Contacts NO3
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 1000 V
Rated Operational Power AC-3 (Pe)(415 V) 9 kW
Max Electrical Switching Frequency(AC-1) 600 cycles per hour
Max Mechanical Switching Frequency3600 cycles per hour
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 30 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 17 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
Rated Operational Current DC-13 (Ie)(24 V) 6 / 144 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 140 A
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 30 A
Product RangeAL Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBL183001R8801, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.