ABB Isolator E203/125r · 2CDE283001R01252CDE283001R0125↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationIsolator · 3P (TP) · 125 A · 25 kA · 230 / 400 V AC
Brand SKU2CDE283001R0125
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB Isolator E203/125r · 2CDE283001R0125

Rating: 125 A
Poles: 3P
₹2,176/pcincl. GST-53%
₹1,844 + 18% GST · MRP ₹4,610
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹2,176 /pc incl. GST
Free delivery over ₹4,000

ABB Isolator E203/125r · 2CDE283001R0125: Elume price today ₹2,176 per pc incl. GST, 53% below the ₹4,610 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹1,658, ₹518 less than here.

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹4,933₹4,016₹3,099₹2,182₹1,265₹4,610₹2,176₹1,658
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹2,176
Avg market price
₹1,658
MRP
₹4,610
Lowest in view · 10 Aug
₹1,360
Highest in view · 3 Oct
₹2,176
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Breaking capacity
Price
ISOLATOR
TP
125 A
n/a
25 kA
₹1,844 +GST /pc
₹2,176 incl. GST
Viewing above ↑
ISOLATOR
TP
125 A
n/a
-
₹1,458 +GST /pc
₹1,720 incl. GST
ISOLATOR
TP
125 A
n/a
-
₹2,238 +GST /pc
₹2,641 incl. GST
ISOLATOR
TP
125 A
n/a
-
₹20,760 +GST /pc
₹24,497 incl. GST
ISOLATOR
TP
125 A
n/a
-
₹35,754 +GST /pc
₹42,190 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹2,067/pc on this product, applied automatically

These devices are suitable for commanding loads and they are realized according EN 60947-3 and EN 60669-1 respectively. Fast removal without dismantling of the busbar. Captive screws with recessed/slotted head. Pozidrive size 2. Add-on of up to 3 auxiliary contact S2C-H6R possible Integrated lay-on edge for labeling system ILS. Locking device as accessories for unauthorized ON/OFF. Approval: VDE,

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB Isolator E203/125r · 2CDE283001R0125 · 2CDE283001R0125
Device typeIsolator (switch disconnector)
Poles3P (TP)
Rated current125 A
Breaking capacity25 kA
Voltage protection level (Up)4 kV
Rated voltage230 / 400 V AC
Frequency50/60 Hz
Service breaking capacity (Ics)6 kA
Width3 modules (52.5 mm)
Ingress protectionIP10
Reference standardIEC/EN 60947-3
Net weight0.29 kg
Current rating125 A
BrandABB
Brand SKU2CDE283001R0125
ELINEP47C66DHC
Sold asPer pc
Ratings as published by ABB (Elume catalogue; abb.com product data, datasheet 2CSC400002D0209). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
What is the difference between an isolator and an MCB?

An isolator (switch-disconnector) only switches the circuit on and off and does not trip on overload or short circuit, while an MCB provides protection. Isolators are used as main switches in DBs or near equipment for safe maintenance, and must be backed by a suitable MCB, MCCB or fuse.

Can I use an isolator as the main switch in my DB?

Yes, a DP isolator for single-phase or 4P isolator for three-phase is commonly used as the DB incomer, provided protection is given upstream (by the meter-side fuse or MCB) and on each outgoing circuit. Its current rating should be equal to or higher than the upstream protection rating.

Is this isolator safe to switch on load?

Switch-disconnectors to IS/IEC 60947-3 are rated for switching under load according to their utilisation category, such as AC-22 for mixed resistive and inductive loads or AC-23 for motor loads. Check the category on the product before using it to switch motors directly.

What current rating does this isolator have?

It is rated 125 A. Choose a rating at least equal to the upstream MCB or fuse so the isolator is never the weakest link in the circuit.

2 pole or 4 pole isolator - which one do I need?

Use 2 pole for single-phase supply (phase and neutral) and 4 pole for three-phase supply with neutral, so all live conductors are disconnected during maintenance. A 3 pole isolator is used where no neutral is switched, such as some motor feeders.

Can an isolator be locked off for maintenance?

Many isolators and rotary switch-disconnectors have a padlocking provision in the OFF position so no one can switch them on while work is in progress. Check for the lock-off feature if it is needed for your site's safety procedures.

No reviews yet