🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB Miniature Circuit Breaker - SB200 DC - 1P - C - 1.6 ampere · 1SYS251067R09741SYS251067R0974↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationSB201-C1.6DC · System Pro M
Brand SKU1SYS251067R0974
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB Miniature Circuit Breaker - SB200 DC - 1P - C - 1.6 ampere · 1SYS251067R0974

NEW added this week
₹788/pcincl. GST-53%
₹668 + 18% GST · MRP ₹1,670
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹788 /pc incl. GST
Free delivery over ₹4,000

ABB Miniature Circuit Breaker - SB200 DC - 1P - C - 1.6 ampere · 1SYS251067R0974: Elume price today ₹788 per pc incl. GST, 53% below the ₹1,670 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹1,787₹1,523₹1,260₹996₹733₹1,670₹788
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹788
MRP
₹1,670
Lowest in view · 17 Nov
₹788
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹772/pc on this product, applied automatically

System pro M compact SB200 DC Miniature Circuit Breakers are current limiting. They have two different tripping mechanisms, the delayed thermal tripping mechanism for overload protection and the electromechanic tripping mechanism for short circuit protection. They are available in C-characteristics, different configurations (1P, 2P), breaking capacities (up to 6 kA at 240/415 V AC) and rated currents (up to 63A). All MCBs of the product range SB200 DC comply with IS/IEC 60947-2, allowing the use for residential, commercial and industrial applications.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB Miniature Circuit Breaker - SB200 DC - 1P - C - 1.6 ampere · 1SYS251067R0974 · 1SYS251067R0974
Device typeMiniature circuit breaker (MCB)
SeriesSystem Pro M
Poles1P (SP)
Rated current1.6 A
Trip curveC curve
Breaking capacity6 kA
Service breaking capacity (Ics)6000 kA
Operational current (Ie)1.6A
Reference standardIS/IEC 60947-2
Country of originIndia
BrandABB
Brand SKU1SYS251067R0974
ELINE3GC49GFD7
Sold asPer pc
StandardsIS/IEC 60947-2
Package Width88 mm
Package Height76 mm
Package Length19 mm
Number of Poles1
Housing MaterialInsulation Group I, RAL 7035
Rated Voltage (Ur)250 V
Mechanical Endurance20000 cycle
Package Gross Weight0.125 kg
Extended Product TypeSB201-C1.6DC
Tripping CharacteristicC
Rated Current El ED (In)1.6A
Rated Operational Current (Ie)1.6A
Rated Short-Circuit Capacity (Icn)6 kA
Rated Service Short-Circuit Breaking Capacity (Ics)6000 kA
Product RangeSystem Pro M
Ratings as published by ABB (shop.in.abb.com listing for 1SYS251067R0974, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.