ABB ABB AF580-30-11 250-500V 50/60Hz / 250-500V DC Contactor · 1SFL617001R7111 · 1SFL617001R7111
Device typeContactor
SeriesAF Contactors
Poles3P (TP)
Frequency50/60 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Country of originSweden
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SFL617001R7111
ELINE4CK66MR3G
Sold asPer pc
Operate TimeBetween Coil De-energization and NC Contact Closing 50 ... 70 millisecond, Between Coil De-energization and NO Contact Opening 53 ... 73 millisecond, Between Coil Energization and NC Contact Opening 45 ... 115 millisecond, Between Coil Energization and NO
Package Width280 mm
Product ClassBlock Contactors
Terminal TypeMain Circuit: Bars
Package Height310 mm
Package Length375 mm
Number of Poles3
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 12 V - A, Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V - A, Holding at Max. Rated Control Circuit Voltage DC 7.5 V - A, Pull-in at Max. Rated Control Circuit Voltage 5
Rated Frequency (f)Main Circuit 50/60 Hz
Mounted Aux Contacts1 NO, 1 NC
Package Gross Weight15 kg
Extended Product TypeAF580-30-11-71
Rated Frequency Limits25 ... 400 Hz
Ambient Air TemperatureClose to Contactor for Storage -40 ... +70 °C, Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 590 A, (550 ... 600 V AC) Three Phase 578 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 200 hp, (208 V AC) Three Phase 200 hp, (220 ... 240 V AC) Three Phase 250 hp, (440 ... 480 V AC) Three Phase 500 hp, (550 ... 600 V AC) Three Phase 600 hp
General Use Rating UL/CSA(600 V AC) 750 A
Number of Aux Contacts NC1
Number of Aux Contacts NO1
Number of Main Contacts NC0
Number of Main Contacts NO3
Max Operating Voltage UL/CSAMain Circuit 600 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Operational Power AC-3 (Pe)(1000 V) 355 KWT, (220 / 230 / 240 V) 160 KWT, (380 / 400 V) 315 KWT, (415 V) 355 KWT, (440 V) 355 KWT, (500 V) 400 KWT, (690 V) 500 KWT
Max Electrical Switching FrequencyAC-1 300 cycles per hour, AC-2 / AC-4 60 cycles per hour, AC-3 300 cycles per hour
Max Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 250-500V; 60 Hz 250-500V; DC Operation 250-500V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 800 A, (1000 V) 55 °C 700 A, (1000 V) 70 °C 580 A, (690 V) 40 °C 800 A, (690 V) 55 °C 700 A, (690 V) 70 °C 580 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 250 A, (220 / 230 / 240 V) 55 °C 580 A, (380 / 400 V) 55 °C 580 A, (415 V) 55 °C 580 A, (440 V) 55 °C 580 A, (500 V) 55 °C 580 A, (690 V) 55 °C 500 A
Rated Operational Current DC-1 (Ie)(110 V) 1-Pole, 40 °C 800 A, (110 V) 2 Poles in Series, 40 °C 800 A, (220 V) 3 Poles in Series, 40 °C 800 A, (600 V) 3 Poles in Series, 40 °C 800 A, (850 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-3 (Ie)(110 V) 1-Pole, 40 °C 800 A, (110 V) 2 Poles in Series, 40 °C 800 A, (220 V) 3 Poles in Series, 40 °C 800 A, (600 V) 3 Poles in Series, 40 °C 800 A, (850 V) 3 Poles in Series, 40 °C 800 A
Rated Operational Current DC-5 (Ie)(110 V) 1-Pole, 40 °C 800 A, (110 V) 2 Poles in Series, 40 °C 800 A, (220 V) 3 Poles in Series, 40 °C 800 A, (600 V) 3 Poles in Series, 40 °C 800 A, (850 V) 3 Poles in Series, 40 °C 800 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A, at 40 °C Ambient Temp, in Free Air,
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 800 A
Automation & Control Rated Operational VoltageMain Circuit 1000 V
Rated Making Capacity AC-3 acc. to IEC 60947-4-110 x Ie AC-3
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-18 x Ie AC-3
Product RangeAF Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SFL617001R7111, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.