Device typeContactor
SeriesAF Contactors
Poles3P (TP)
Frequency50/60 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Country of originSweden
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SFL607002R1411
ELINEM677R6CG9
Sold asPer pc
Operate TimeBetween Coil De-energization and NO Contact Opening 37 ... 47 millisecond, Between Coil Energization and NO Contact Closing 25 ... 55 millisecond
Package Width263 mm
Product ClassBlock Contactors
Terminal TypeMain Circuit: Bars
Package Height289 mm
Package Length203 mm
Number of Poles3
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 20.4 V - A, Holding at Max. Rated Control Circuit Voltage 60 Hz 20.4 V - A, Holding at Max. Rated Control Circuit Voltage DC 4.7 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz
Rated Frequency (f)Main Circuit 50/60 Hz
Mounted Aux Contacts1 NO, 1 NC
Package Gross Weight4.6 kg
Extended Product TypeAF370-30-11-14
Rated Frequency Limits25 ... 400 Hz
Ambient Air TemperatureClose to Contactor for Storage -40 ... +70 °C, Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 361 A, (550 ... 600 V AC) Three Phase 336 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 125 hp, (208 V AC) Three Phase 125 hp, (220 ... 240 V AC) Three Phase 150 hp, (440 ... 480 V AC) Three Phase 300 hp, (550 ... 600 V AC) Three Phase 350 hp
General Use Rating UL/CSA(600 V AC) 520 A
Number of Aux Contacts NC1
Number of Aux Contacts NO1
Number of Main Contacts NC0
Number of Main Contacts NO3
Max Operating Voltage UL/CSAMain Circuit 600 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Operational Power AC-3 (Pe)(1000 V) 200 KWT, (220 / 230 / 240 V) 110 KWT, (380 / 400 V) 200 KWT, (415 V) 200 KWT, (440 V) 200 KWT, (500 V) 250 KWT, (690 V) 315 KWT
Max Electrical Switching FrequencyAC-1 300 cycles per hour, AC-2 / AC-4 150 cycles per hour, AC-3 300 cycles per hour
Max Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 250-500V; 60 Hz 250-500V; DC Operation 250-500V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 400 A, (1000 V) 55 °C 350 A, (1000 V) 70 °C 290 A, (690 V) 40 °C 600 A, (690 V) 55 °C 500 A, (690 V) 70 °C 400 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 141 A, (220 / 230 / 240 V) 55 °C 370 A, (380 / 400 V) 55 °C 370 A, (415 V) 55 °C 370 A, (440 V) 55 °C 370 A, (500 V) 55 °C 315 A, (690 V) 55 °C 315 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 450 A, (220 V) 3 Poles in Series, 40 °C 450 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A, at 40 °C Ambient Temp, in Free Air, f
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 600 A
Automation & Control Rated Operational VoltageMain Circuit 1000 V
Rated Making Capacity AC-3 acc. to IEC 60947-4-110 x Ie AC-3
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-18 x Ie AC-3
Product RangeAF Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SFL607002R1411, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.