ABB AF205-40-00-11 Contactor · 1SFL527102R11001SFL527102R1100↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationAF205-40-00-11 · AF Contactors
Brand SKU1SFL527102R1100
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB AF205-40-00-11 Contactor · 1SFL527102R1100

NEW added this week
₹86,998/pcincl. GST-53%
₹73,727 + 18% GST · MRP ₹1,84,317
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹86,998 /pc incl. GST
Delivery ₹1,000, ships insured

ABB AF205-40-00-11 Contactor · 1SFL527102R1100: Elume price today ₹86,998 per pc incl. GST, 53% below the ₹1,84,317 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹1,97,219₹1,68,141₹1,39,064₹1,09,986₹80,908₹1,84,317₹86,998
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹86,998
MRP
₹1,84,317
Lowest in view · 17 Nov
₹86,998
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹82,648/pc on this product, applied automatically

A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 24-60 V, 50 and 60 Hz, 20-60 V DC

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB AF205-40-00-11 Contactor · 1SFL527102R1100 · 1SFL527102R1100
Device typeContactor
SeriesAF Contactors
Poles4P (FP)
Frequency60 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Country of originSweden
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SFL527102R1100
ELINEMCF4J4R3C
Sold asPer pc
Operate TimeBetween Coil De-energization and NO Contact Opening 45 ... 80 millisecond, Between Coil Energization and NO Contact Closing 25 ... 60 millisecond
Package Width166 mm
Product ClassBlock Contactors
Terminal TypeMain Circuit: Bars
Package Height180 mm
Package Length238 mm
Number of Poles4
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 6 V - A, Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V - A, Holding at Max. Rated Control Circuit Voltage DC 2.5 W, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 165 vo
Rated Frequency (f)Main Circuit 60 Hz
Mounted Aux Contacts0 NO, 0 NC
Package Gross Weight3.9 kg
Extended Product TypeAF205-40-00-11
Rated Frequency Limits25 ... 400 Hz
Ambient Air TemperatureClose to Contactor for Storage -40 ... +70 °C, Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
General Use Rating UL/CSA(600 V AC) 250 A
Number of Aux Contacts NC0
Number of Aux Contacts NO0
Number of Main Contacts NC0
Number of Main Contacts NO4
Max Operating Voltage UL/CSAMain Circuit 600 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 55 KWT, (380 / 400 V) 110 KWT, (415 V) 110 KWT, (440 V) 132 KWT
Max Electrical Switching FrequencyAC-1 300 cycles per hour
Max Mechanical Switching Frequency300 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24-60V; 60 Hz 24-60V; DC Operation 20-60V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 250 A, (1000 V) 60 °C 225 A, (1000 V) 70 °C 185 A, (690 V) 40 °C 350 A, (690 V) 60 °C 250 A, (690 V) 70 °C 200 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 55 °C 205 A, (380 / 400 V) 55 °C 205 A, (415 V) 55 °C 205 A, (440 V) 55 °C 205 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A, at 40 °C Ambient Temp, in Free Air, fr
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A
Automation & Control Rated Operational VoltageMain Circuit 1000 V
Rated Making Capacity AC-3 acc. to IEC 60947-4-110 x Ie AC-3
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-18 x Ie AC-3
Product RangeAF Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SFL527102R1100, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet