ABB ABB A145-30-11 24V 50Hz / 24V 60Hz Contactor · 1SFL471001R8111 · 1SFL471001R8111
Device typeContactor
SeriesA Contactors
Poles3P (TP)
Frequency50/60 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Country of originSweden
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SFL471001R8111
ELINER99JP6J9G
Sold asPer pc
Operate TimeBetween Coil De-energization and NC Contact Closing 5 ... 10 millisecond, Between Coil De-energization and NO Contact Opening 9 ... 13 millisecond, Between Coil Energization and NC Contact Opening 8 ... 22 millisecond, Between Coil Energization and NO Con
Package Width178 mm
Product ClassBlock Contactors
Terminal TypeMain Circuit: Bars
Package Height167 mm
Package Length232 mm
Number of Poles3
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 35 V - A, Holding at Max. Rated Control Circuit Voltage 60 Hz 40 V - A, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 550 V - A, Pull-in at Max. Rated Control Circuit Voltag
Rated Frequency (f)Main Circuit 50/60 Hz
Mounted Aux Contacts1 NO, 1 NC
Package Gross Weight3.5 kg
Extended Product TypeA145-30-11-81
Rated Frequency Limits25 ... 400 Hz
Ambient Air TemperatureClose to Contactor for Storage -40 ... +70 °C, Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... +50 °C, Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +70 °C
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 124 A, (550 ... 600 V AC) Three Phase 125 A
Horsepower Rating UL/CSA(200 V AC) Three Phase 40 hp, (208 V AC) Three Phase 40 hp, (220 ... 240 V AC) Three Phase 50 hp, (440 ... 480 V AC) Three Phase 100 hp, (550 ... 600 V AC) Three Phase 125 hp
General Use Rating UL/CSA(600 V AC) 230 A
Number of Aux Contacts NC1
Number of Aux Contacts NO1
Number of Main Contacts NC0
Number of Main Contacts NO3
Max Operating Voltage UL/CSAMain Circuit 600 V
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 45 KWT, (380 / 400 V) 75 KWT, (415 V) 75 KWT, (440 V) 75 KWT, (500 V) 90 KWT, (690 V) 110 KWT
Max Electrical Switching FrequencyAC-1 300 cycles per hour, AC-2 / AC-4 150 cycles per hour, AC-3 300 cycles per hour
Max Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24V; 60 Hz 24V
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 180 A, (1000 V) 55 °C 180 A, (1000 V) 70 °C 180 A, (690 V) 40 °C 250 A, (690 V) 55 °C 230 A, (690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie)(1000 V) 55 °C 80 A, (220 / 230 / 240 V) 55 °C 145 A, (380 / 400 V) 55 °C 145 A, (415 V) 55 °C 145 A, (440 V) 55 °C 145 A, (500 V) 55 °C 145 A, (690 V) 55 °C 120 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 250 A, (220 V) 3 Poles in Series, 40 °C 250 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A, at 40 °C Ambient Temp, in Free Air, fr
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 250 A
Automation & Control Rated Operational VoltageMain Circuit 690 V
Rated Making Capacity AC-3 acc. to IEC 60947-4-110 x Ie AC-3
Rated Breaking Capacity AC-3 acc. to IEC 60947-4-18 x Ie AC-3
Product RangeA Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SFL471001R8111, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.