🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB AF65-30-00-11 24-60V50/60HZ 20-60VDC Contactor · 1SBL387001R11001SBL387001R1100↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationAF65-30-00-11 · AF Contactors
Brand SKU1SBL387001R1100
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB AF65-30-00-11 24-60V50/60HZ 20-60VDC Contactor · 1SBL387001R1100

NEW added this week
₹18,193/pcincl. GST-53%
₹15,418 + 18% GST · MRP ₹38,546
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹18,193 /pc incl. GST
Free pan-India delivery

ABB AF65-30-00-11 24-60V50/60HZ 20-60VDC Contactor · 1SBL387001R1100: Elume price today ₹18,193 per pc incl. GST, 53% below the ₹38,546 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹41,244₹35,163₹29,082₹23,001₹16,919₹38,546₹18,193
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹18,193
MRP
₹38,546
Lowest in view · 17 Nov
₹18,193
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹17,283/pc on this product, applied automatically

AF65 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz or 20...500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB AF65-30-00-11 24-60V50/60HZ 20-60VDC Contactor · 1SBL387001R1100 · 1SBL387001R1100
Device typeContactor
SeriesAF Contactors
Frequency50 / 60 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Country of originFrance
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL387001R1100
ELINE29CGFJR96
Sold asPer pc
Operate TimeBetween Coil De-energization and NC Contact Closing 19 ... 105 millisecond, Between Coil De-energization and NO Contact Opening 17 ... 100 millisecond, Between Coil Energization and NC Contact Opening 38 ... 95 millisecond, Between Coil Energization and N
Package Width150 mm
Product ClassBlock Contactors
Terminal TypeScrew Terminals
Package Height97 mm
Package Length150 mm
Rated Frequency (f)Main Circuit 50 / 60 Hz
Mounted Aux Contacts0 NO, 0 NC
Package Gross Weight1.07 kg
Extended Product TypeAF65-30-00-11
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C, Close to Contactor without Thermal O/L Relay -40 ... +70 °C, Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Full Load Amps Motor Use(440 ... 480 V AC) Three Phase 50 A, (550 ... 600 V AC) Three Phase 60 A, (120 V AC) Single Phase 5 A, (200 ... 208 V AC) Three Phase 20 A, (220 ... 240 V AC) Three Phase 25 A, (240 V AC) Single Phase 15 A
Horsepower Rating UL/CSA(220 ... 240 V AC) Three Phase 25 hp, (440 ... 480 V AC) Three Phase 50 hp, (550 ... 600 V AC) Three Phase 60 hp, (120 V AC) Single Phase 5 hp, (200 ... 208 V AC) Three Phase 20 hp, (240 V AC) Single Phase 15 hp
Number of Aux Contacts NC0
Number of Aux Contacts NO0
Number of Main Contacts NC0
Number of Main Contacts NO3
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 18.5 KWT, (380 / 400 V) 30 KWT, (415 V) 37 KWT, (440 V) 37 KWT, (500 V) 37 KWT, (690 V) 37 KWT, (400 V) 30 KWT
Max Electrical Switching FrequencyAC-1 600 cycles per hour, AC-2 / AC-4 150 cycles per hour, AC-3 1200 cycles per hour
Max Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24-60V; 50 Hz / 60 Hz 24-60V; 60 Hz 24-60V; DC Operation 20-60V
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 105 A, (690 V) 60 °C 90 A, (690 V) 70 °C 80 A
Rated Operational Current AC-3 (Ie)(220 / 230 / 240 V) 60 °C 65 A, (380 / 400 V) 60 °C 65 A, (415 V) 60 °C 65 A, (440 V) 60 °C 65 A, (500 V) 60 °C 55 A, (690 V) 60 °C 39 A
Rated Short-time Withstand Current (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A, at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A, at 40 °C Ambient Temp, in Free Air, fro
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors q = 40 °C 105 A
Automation & Control Rated Operational VoltageMain Circuit 690 V
Product RangeAF Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBL387001R1100, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.

No reviews yet