ABB UA50-30-00 24V 50Hz / 24V 60Hz Contactor · 1SBL351022R81001SBL351022R8100↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationUA50-30-00 24V 50Hz / 24V 60Hz · Capacitor Duty Contactors
Brand SKU1SBL351022R8100
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB UA50-30-00 24V 50Hz / 24V 60Hz Contactor · 1SBL351022R8100

NEW added this week
₹12,638/pcincl. GST-53%
₹10,710 + 18% GST · MRP ₹26,775
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹12,638 /pc incl. GST
Free pan-India delivery

ABB UA50-30-00 24V 50Hz / 24V 60Hz Contactor · 1SBL351022R8100: Elume price today ₹12,638 per pc incl. GST, 53% below the ₹26,775 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹28,649₹24,425₹20,201₹15,977₹11,753₹26,775₹12,638
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹12,638
MRP
₹26,775
Lowest in view · 17 Nov
₹12,638
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹12,006/pc on this product, applied automatically

UA50 3-pole contactors for capacitor switching, can be used for the switching of capacitor banks whose inrush current peaks are less than or equal to 100 times nominal rms current. The table below gives the permissible powers according to operational voltage and temperature close to the contactor. It also specifies the maximum peak current Î values accepted by the contactor. The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. In these conditions, electrical durability of contactors is equal to 100 000 operating cycles. The UA.. series 3-pole contactors are of the block type design. - Main poles: 3 main poles - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB UA50-30-00 24V 50Hz / 24V 60Hz Contactor · 1SBL351022R8100 · 1SBL351022R8100
Device typeContactor
SeriesCapacitor Duty Contactors
Frequency25 ... 400 Hz
Insulation voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Country of originFrance
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL351022R8100
ELINE2DRJRDGCM
Sold asPer pc
Operate TimeBetween Coil De-energization and NO Contact Opening 4 ... 11 millisecond, Between Coil Energization and NO Contact Closing 8 ... 27 millisecond
Package Width140 mm
Product ClassBlock Contactors
Terminal TypeScrew Terminals
Package Height96 mm
Package Length146 mm
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 18 5.5 V - A, Holding at Max. Rated Control Circuit Voltage 60 Hz 18 5.5 V - A, Pull-in at Max. Rated Control Circuit Voltage 50 Hz 190 V - A, Pull-in at Max. Rated Control Circui
Mounted Aux Contacts0 NO, 0 NC
Package Gross Weight1.16 kg
Extended Product TypeUA50-30-00 24V 50Hz / 24V 60Hz
Rated Frequency Limits25 ... 400 Hz
Ambient Air TemperatureClose to Contactor for Storage -60 ... +80 °C, Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C, Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C
Number of Aux Contacts NC0
Number of Aux Contacts NO0
Number of Main Contacts NC0
Number of Main Contacts NO3
Rated Insulation Voltage (Ui)acc. to UL/CSA 600 V, acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
Rated Operational Power AC-3 (Pe)(220 / 230 / 240 V) 15 KWT, (380 / 400 V) 22 KWT, (415 V) 25 KWT, (440 V) 25 KWT, (500 V) 30 KWT, (690 V) 30 KWT
Max Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 24V; 60 Hz 24V
Rated Operational Power AC-6b (Pe)(230 / 240 V) 40 °C, 50 / 60 Hz 20 KVR, (230 / 240 V) 55 °C, 50 / 60 Hz 20 KVR, (230 / 240 V) 70 °C, 50 / 60 Hz 19 KVR, (400 / 415 V) 40 °C, 50 / 60 Hz 33 KVR, (400 / 415 V) 70 °C, 50 / 60 Hz 32 KVR, (400 / 415 V) 55 °C, 50 / 60 Hz 33 KVR, (440 V) 40 °C,
Automation & Control Rated Operational VoltageMain Circuit 690 V
Product RangeCapacitor Duty Contactors
Ratings as published by ABB (shop.in.abb.com listing for 1SBL351022R8100, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.