ABB UA30-30-10RA 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL281024R80101SBL281024R8010↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationContactor · 3P (TP) · Auxiliary Circuit 690 V
Brand SKU1SBL281024R8010
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB UA30-30-10RA 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL281024R8010

₹5,759/pcincl. GST-53%
₹4,881 + 18% GST · MRP ₹12,201
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹5,759 /pc incl. GST
Free pan-India delivery

ABB UA30-30-10RA 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL281024R8010: Elume price today ₹5,759 per pc incl. GST, 53% below the ₹12,201 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹4,113, ₹1,646 less than here. The lowest tracked seller lists it at ₹4,113, ₹1,646 below it (tell us and we match it).

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹13,055₹10,639₹8,222₹5,806₹3,390₹12,201₹5,759₹4,113
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹5,759
Avg market price
₹4,113
MRP
₹12,201
Lowest in view · 10 Aug
₹3,645
Highest in view · 3 Oct
₹5,759
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹5,471/pc on this product, applied automatically

UA30..RA 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB UA30-30-10RA 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL281024R8010 · 1SBL281024R8010
Device typeContactor
Poles3P (TP)
Rated voltageAuxiliary Circuit 690 V
FrequencyAuxiliary Circuit 50 / 60 Hz
Insulation voltage (Ui)acc. to IEC 60947-4-1 1000 V
Impulse withstand (Uimp)8 kV
Width3 modules (54 mm)
Terminal capacityFlexible with Cable End 2.5 ... 4 mm²
Ingress protectionIP20
Reference standardIEC/EN 60947-1, IEC/EN 60947-4-1
Net weight0.81 kg
Country of originBulgaria
BrandABB
Brand SKU1SBL281024R8010
ELINEDFK2HDDKH
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 1SBC100214C0202; shop.in.abb.com listing for 1SBL281024R8010, 23 Sep 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.