🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB A12-30-01 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL161001R80011SBL161001R8001↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationA12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary conta
Brand SKU1SBL161001R8001
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB A12-30-01 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL161001R8001

₹1,547/pcincl. GST-53%
₹1,311 + 18% GST · MRP ₹3,276
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹1,547 /pc incl. GST
Free delivery over ₹4,000

ABB A12-30-01 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL161001R8001: Elume price today ₹1,547 per pc incl. GST, 53% below the ₹3,276 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹1,141, ₹406 less than here. The lowest tracked seller lists it at ₹1,141, ₹406 below it (tell us and we match it).

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹3,505₹2,856₹2,207₹1,558₹909₹3,276₹1,547₹1,141
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹1,547
Avg market price
₹1,141
MRP
₹3,276
Lowest in view · 10 Aug
₹977
Highest in view · 3 Oct
₹1,547
For panel builders
Buying this for a panel?
The price above is for a single piece. Send the whole BOM in any file and a person quotes the job within 24 hours.
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹1,470/pc on this product, applied automatically

ABB A12-30-01 220-230V 50Hz / 230-240V 60Hz Contactor (ABB article 1SBL161001R8001) belongs to ABB's A Contactors range, listed under Contactors upto 100A. A12 contactors are mainly used for controlling 3-phase motors and generally for controlling power circuits up to 690 V AC or 220 V DC. The contactors can also be used for many other applications such as isolation, capacitor switching, lighting. The A... series 1-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available. Sold by Elume with a GST invoice and delivery across India.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB A12-30-01 220-230 V 50 Hz / 230-240 V 60 Hz Contactor · 1SBL161001R8001 · 1SBL161001R8001
Device typeMiniature circuit breaker (MCB)
Poles3-pole
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SBL161001R8001
ELINEJ66F6RHMC
Sold asPer pc
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
How do I choose a contactor for my motor?

Select by the contactor's AC-3 current (or kW) rating at your supply voltage, which should be at least the motor's full-load current from the nameplate. Do not go by the higher AC-1 rating, which applies only to resistive loads (contactors are covered by IS/IEC 60947-4-1).

What is the difference between AC-1 and AC-3 rating?

AC-1 is for non-inductive or slightly inductive loads like heaters, while AC-3 is for starting and stopping squirrel cage motors. The same contactor has a much lower AC-3 rating than AC-1, and AC-4 (inching or plugging) is even more demanding.

Does a contactor protect the motor?

No. A contactor only switches the motor on and off; overload protection needs a thermal overload relay and short-circuit protection needs an MPCB, MCB, MCCB or fuses upstream.

Why is my contactor humming or chattering?

Common causes are low or fluctuating control voltage, a wrong coil voltage, dust or rust on the magnet faces, or a broken shading ring. Check the supply at the coil terminals first, then clean or replace the contactor if needed.

How many auxiliary contacts does this have and can I add more?

Most contactors have built-in auxiliary contacts (NO and/or NC) for holding and interlocking circuits, and many allow add-on auxiliary blocks on the front or side. Check the contact configuration and add-on compatibility in the product details.

How many contactors do I need for a star-delta starter?

A star-delta starter uses three contactors (main, delta and star), a star-delta timer and an overload relay. The main and delta contactors are typically sized at about 58% of the motor current and the star contactor smaller, as per the manufacturer's selection table.