ABB MS132-25T Circuit Breaker for Primary Transformer Protection · 1SAM340000R10141SAM340000R1014↓ 53% off MRP
BrandABB
CategorySwitchgear
SpecificationMS132-25T · MO-MS
Brand SKU1SAM340000R1014
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB MS132-25T Circuit Breaker for Primary Transformer Protection · 1SAM340000R1014

NEW added this week
₹9,446/pcincl. GST-53%
₹8,005 + 18% GST · MRP ₹20,013
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹9,446 /pc incl. GST
Free pan-India delivery

ABB MS132-25T Circuit Breaker for Primary Transformer Protection · 1SAM340000R1014: Elume price today ₹9,446 per pc incl. GST, 53% below the ₹20,013 MRP. The price has held steady for the last 30 days.

Price history
Elume price over time, day by day. Market comparison appears once we track this item.
16 Nov to 22 Nov
₹21,414₹18,257₹15,099₹11,942₹8,785₹20,013₹9,446
16 Nov17 Nov18 Nov19 Nov20 Nov21 Nov22 Nov
Elume today
₹9,446
MRP
₹20,013
Lowest in view · 17 Nov
₹9,446
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹8,974/pc on this product, applied automatically

The circuit breaker for transformer protection MS132-25T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 25 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 50 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB MS132-25T Circuit Breaker for Primary Transformer Protection · 1SAM340000R1014 · 1SAM340000R1014
Device typeManual motor starter (MPCB)
SeriesMO-MS
Poles3P (TP)
Frequency50 Hz/Main Circuit 60 Hz
Service breaking capacity (Ics)50 kA
Operational current (Ie)25A
Insulation voltage (Ui)690 V
Country of originGermany
Reference standardIS/IEC 60898-1
BrandABB
Brand SKU1SAM340000R1014
ELINEF7FKGJGDK
Sold asPer pc
Package Width92 mm
Terminal TypeScrew Terminals
Package Height50 mm
Package Length102 mm
Number of Poles3
Rated Frequency (f)Main Circuit 50 Hz/Main Circuit 60 Hz
Package Gross Weight0.325 kg
Extended Product TypeMS132-25T
Ambient Air TemperatureAround the Enclosure 0 ... +40 °C, Operation -25 ... +70 °C, Storage -50 ... +80 °C
Full Load Amps Motor Use(120 V AC) Single Phase 24 A, (220 ... 240 V AC) Single Phase 17 A
Rated Insulation Voltage (Ui)690 V
Rated Operational Current (Ie)25A
Automation & Control Rated Operational VoltageMain Circuit 690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)(400 V AC) 50 kA
Product RangeMO-MS
Ratings as published by ABB (shop.in.abb.com listing for 1SAM340000R1014, 15 Nov 2026). Verify critical parameters against the datasheet before specifying.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Which MCB rating do I need for a 1.5 ton split AC?

Many 1.5 ton split ACs are put on a dedicated 16A or 20A MCB (C curve is common) with 2.5 or 4 sq mm copper wire, depending on the rated current on the nameplate and the cable run. Follow the AC's installation manual and have a licensed electrician size the MCB to protect the cable, not just the appliance.

What is the difference between B, C and D curve MCBs?

The curve sets how fast the MCB trips on a surge: B trips at 3-5 times rated current, C at 5-10 times and D at 10-20 times (IS/IEC 60898-1). B suits lighting and resistive loads, C is the usual choice for homes with ACs, fans, motors and pumps, and D is for high inrush loads like transformers and large motors.

Should I use SP or DP MCB for my geyser or AC?

A DP (double pole) MCB switches off both phase and neutral, giving full isolation for high-load or wet-area appliances like geysers, ACs and the main incomer. SP MCBs are fine for normal lighting and socket circuits where only the phase needs protection.

Is 6kA or 10kA breaking capacity better for home?

Breaking capacity is the maximum fault current the MCB can safely interrupt; 6kA is adequate for most homes and 10kA is recommended near large transformers, in commercial buildings or industrial sites where prospective fault current is higher. Choosing 10kA does not change how the MCB behaves on normal overloads.

Will this MCB fit in my existing DB of another brand?

Most modular MCBs mount on a standard 35mm DIN rail and are one module (about 18mm) wide per pole, so they usually physically fit. The front cover cutout height and busbar terminal type can differ between brands, so check the cover alignment before mixing brands in one DB.

Does an MCB protect against electric shock?

No. An MCB protects wiring against overload and short circuit only; protection against shock and earth leakage needs an RCCB or RCBO (typically 30mA) in the same circuit.

No reviews yet