🚚 Free delivery over ₹4,000 pan-India · we also ship worldwide · Buying in bulk? Get a quote in 24 hours →
ABB F204 RCCB · 4P (FP) · 40 A · 300 mA · Type AC · 2CSF204001R34002CSF204001R3400↓ 5% off MRP
BrandABB
CategorySwitchgear
SpecificationRCCB · 4P (FP) · 40 A · 300 mA · Type AC · 230 … 400 V AC
Brand SKU2CSF204001R3400
AvailabilityIn stock · ships in 24h
DeliveryPan-India · 7 working days
ABB· In stock
Visit the ABB store

ABB F204 RCCB · 4P (FP) · 40 A · 300 mA · Type AC · 2CSF204001R3400

₹5,171/pcincl. GST-5%
₹4,382 + 18% GST · MRP ₹5,430
Add to cart
Buy now
  • Secured by Razorpay · UPI, cards, net banking, wallets
  • GST invoice, claim input tax credit
  • Tracked delivery, 5 to 7 working days
✓ Full brand warranty on every order
✓Lowest price guarantee · found it cheaper? We match it.
💳 30 Day credit facility available launching soon - join waitlist.
₹5,171 /pc incl. GST
Free pan-India delivery

ABB F204 RCCB · 4P (FP) · 40 A · 300 mA · Type AC · 2CSF204001R3400: Elume price today ₹5,171 per pc incl. GST, 5% below the ₹5,430 MRP. The price has held steady for the last 30 days. The average price across the sellers we track is ₹4,137, ₹1,034 less than here. The lowest tracked seller lists it at ₹4,137, ₹1,034 below it (tell us and we match it).

Price history
Elume price vs the average market price across the sellers we track, day by day. Tap a legend entry to show or hide a line.
25 May to 22 Nov
₹5,810₹5,300₹4,790₹4,280₹3,770₹5,430₹5,171₹4,137
May 26Jun 26Aug 26Sep 26Oct 26Nov 26Nov 26
Elume today
₹5,171
Avg market price
₹4,137
MRP
₹5,430
Lowest in view · 10 Aug
₹4,054
Highest in view · 3 Oct
₹5,430
Same key specifications, different brands - matched on spec, never on looks. Tap a product to open it.Full comparison page →
Product
Type
Poles
Rating
Curve
Sensitivity
Price
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹4,382 +GST /pc
₹5,171 incl. GST
Viewing above ↑
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹2,420 +GST /pc
₹2,856 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹2,700 +GST /pc
₹3,186 incl. GST
RCCB
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹3,424 +GST /pc
₹4,040 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹3,584 +GST /pc
₹4,229 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹5,043 +GST /pc
₹5,951 incl. GST
RCCB
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹5,439 +GST /pc
₹6,418 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹5,460 +GST /pc
₹6,443 incl. GST
RCCB · Type AC
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹6,509 +GST /pc
₹7,681 incl. GST
RCCB
4P / 3P+N (three phase)
40 A
n/a
300 mA
₹8,098 +GST /pc
₹9,556 incl. GST
🏷️
100% genuine
Brand-authorised stock with full manufacturer warranty
🧾
GST invoice
Tax invoice on every order · GST billing with tax split
🚚
Pan-India delivery
7 working days to your location
📦
Wholesale built in
Wholesale price at 15+ units: ₹4,912/pc on this product, applied automatically

The RCCBs F200 series assures protection to people and installations against fault current to earth. A large offer for standard instantaneous and selective AC and A types is completed with some configurations for special applications.

As published by ABB. Verify critical parameters against the datasheet before specifying.
ABB ABB F204 RCCB · 4P (FP) · 40 A · 300 mA · Type AC · 2CSF204001R3400 · 2CSF204001R3400
Device typeResidual current circuit breaker (RCCB)
Poles4P (FP)
Rated current40 A
Sensitivity (IΔn)300 mA
RCCB typeType AC
Rated voltage230 … 400 V AC
Frequency50/60 Hz
Insulation voltage (Ui)500 V
Impulse withstand (Uimp)4 kV
Width4 modules (70 mm)
Terminal capacityBusbar 10 mm²
Ingress protectionIP20
Reference standardIEC/EN 61008, UL 1053
Net weight0.36 kg
Current rating40 A
Sensitivity300 mA
BrandABB
Brand SKU2CSF204001R3400
ELINEJHRFCR424
Sold asPer pc
Ratings as published by ABB (abb.com product data, datasheet 9AKK107991A8329; Product name; Elume catalogue). Verify critical parameters against the datasheet before specifying.
The letter after the sensitivity says which earth-fault currents the breaker can sense. Every type trips on a plain AC leak; the higher types also catch the leaks electronics produce. Same rating, different type, different price.
Type AC
THIS UNIT
Senses sinusoidal AC leakage only. Enough for lighting, geysers, heaters and plain socket circuits.
Type A
Senses AC and pulsating DC leakage, the kind inverter air conditioners, washing machines, UPS units, solar inverters and EV chargers produce. A Type AC unit can stay blind to those faults. Covers everything Type AC does. The safe default for a modern home.
Type A APR
Type A with high immunity to nuisance tripping: a short delay rides through lightning surges and switching transients. For circuits where a false trip costs more than the delay: servers, refrigeration, long cable runs.
Sensitivity is a separate choice: 30 mA protects people from shock; 100 mA and 300 mA units are for fire protection or as an upstream main. Type definitions per IEC/EN 61008 and 61009.
Read: Contactor Sizing for 400 V and 415 V Motors: kW to Amps, AC-3 Ratings and Overload Relays →
What size contactor do I need for a 7.5 kW motor?
A 7.5 kW three-phase motor at 400 V draws about 14.5 A, so a contactor rated at least 16 to 18 A at AC-3 is the usual choice, with an overload relay set to the nameplate current.
What is the difference between AC-1 and AC-3?
AC-1 is the rating for resistive loads such as heaters; AC-3 is the rating for switching squirrel-cage motors in normal duty. Motors are always sized on the AC-3 figure, which is lower.
How many amps per kW for a three-phase motor?
At 400 V, roughly 2 A per kW for small motors, falling towards about 1.8 A per kW above 30 kW, because larger motors run at a better power factor and efficiency. Use the nameplate for the exact figure.
Is 30mA or 100mA RCCB right for home?

For protecting people from shock, use 30mA on circuits feeding sockets, bathrooms, kitchens and outdoor points. 100mA or 300mA RCCBs are mainly for fire protection and are often used upstream as a main device, with 30mA protection on the final circuits.

What sensitivity is this RCCB?

This RCCB trips at a residual (leakage) current of 300 mA. 30mA is the standard for personal shock protection, while 100mA and 300mA are used for equipment and fire protection.

Does an RCCB need an MCB with it?

Yes. An RCCB only detects earth leakage and does not protect against overload or short circuit, so it must be backed up by an MCB or fuse of a rating given in the manufacturer's data (RCCBs are covered by IS 12640 (Part 1)).

Why does my RCCB keep tripping?

Common causes are genuine leakage from a faulty appliance (often a geyser element, pump or washing machine), moisture in wiring, neutral of one circuit being shared with another, or many electronic loads adding up their small leakages. Switch off all MCBs and turn them on one by one to find the culprit circuit, and have an electrician test insulation; never bypass the RCCB.

What is the difference between Type AC and Type A RCCB?

Type AC detects only sinusoidal AC leakage, while Type A also detects pulsating DC leakage produced by electronic loads like inverter ACs, washing machines, induction cooktops and LED drivers. Type A is the safer choice for modern homes with many electronic appliances; EV chargers and VFDs may need Type B or a charger with built-in DC detection.

Is this a 2 pole or 4 pole RCCB?

The pole configuration of this RCCB is 4. 2 pole is used on single-phase supply and 4 pole on three-phase supply with neutral, and the neutral of every protected circuit must pass through the same RCCB.

How often should I press the test button?

Manufacturers commonly recommend pressing the test button regularly, often once a month; check the interval in the product's instructions. The RCCB should trip immediately, and if it does not, have an electrician check and replace it.

What current rating RCCB do I need - 25A, 40A or 63A?

The RCCB's rated current should be equal to or higher than the MCB or main switch feeding it, because it must carry the full load current. Many Indian homes use 40A or 63A RCCBs at the incomer; for a single circuit, 25A is common.

No reviews yet